Purpose Continuous monitoring of patient movement is crucial to administering safe radiation therapy (RT). Conventional optical approaches often cannot be used when the patient’s surface is blocked by immobilization devices. Millimeter waves (mmWaves) are capable of penetrating nonconductive objects. In this study, we investigated using mmWave technology to monitor patient surface displacements, as well as breathing and cardiac phases, through clothing and body fixtures. Methods A mmWave device was mounted inside the bore of a ring‐based radiotherapy linear accelerator and pointed at a reflective surface on top of the couch. Measurements were obtained at displacements of 10, 7.5, 5.0, 2.5, and 1.0 mm at heights 100, 150, and 200 mm below isocenter. Submillimeter displacements were performed at a height of 200 mm. Additionally, millimeter and submillimeter displacements were measured with and without a gown and body mold placed between the surface and the sensor. The device was programmed to transmit chirp signals at 77–81 GHz. The subject’s surface was detected by fast Fourier transform (FFT) of the reflected chirp signal within a rough range bin. Fine displacements within that range bin were calculated through phase extraction and phase demodulation. The displacement data were sent through two separate bandpass filters with passbands of 0.1–0.6 and 0.8–2.0 Hz to obtain the subject’s breathing and cardiac waveforms, respectively. The breathing and cardiac measurements were compared to those of a Vernier Respiration Monitor Belt and an electrocardiogram (EKG), respectively, to assess validity. Results The device was able to detect millimeter and submillimeter displacements as small as 0.1 mm, as well as monitor displacement with an accuracy within 1 mm in the presence of an obstructive object. The device's breathing and cardiac waveforms exhibited a strong phase correlation between the respiration monitor belt (ρ = 0.9156) and EKG (ρ = 0.7895), respectively. Conclusions The mmWave device can monitor surface displacements with an accuracy better than 0.1 mm without obstructions and better than 1 mm with obstructions. It can also provide real‐time monitoring of breathing and cardiac waveforms simultaneously with high correlation with traditional respiratory and cardiac monitoring devices. Overall, mmWave technology demonstrates potential for motion monitoring in the field of radiation oncology.
Comprehensive analysis of daily, online adaptive plan quality and safety in magnetic resonance imaging (MRI) guided radiation therapy is critical to its widespread use. Artificial neural network models developed with offline plans created after simulation were used to analyze and compare online plans that were adapted and reoptimized in real time prior to treatment. Roughly one third of 60 Co adapted plans were of inferior quality relative to fully optimized, offline plans, but MRI-linac adapted plans were essentially equivalent to offline plans. The models also enabled clear justification that MRI-linac plans are superior to 60 Co in an overwhelming majority of cases.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.