A prospective clinical study of 17 patients with a histologic diagnosis of colorectal carcinoma proved at colonoscopy and surgery was performed with indium-111 anticarcinoembryonic-antigen (CEA) monoclonal antibody (MoAb), ZCE-025. MoAb scanning depicted nine of 16 primary colorectal carcinomas on planar scintigrams (true-positive findings = 56%) and ten of 16 lesions on single-photon emission computed tomography (SPECT) scans (true-positive findings = 62%). Liver metastases were detected in three of three patients, and lymph node metastases were detected in one of four patients. Immunohistochemical examination for CEA in resected colorectal cancer tissues demonstrated a positive correlation between MoAb imaging of primary lesions and cytoplasmic-stromal intracellular CEA distribution. There was no correlation between CEA serum levels and lesion detectability with MoAb scanning.
Previous studies of insulin binding to placentas of both insulin-dependent and untreated gestational diabetic patients have described placentas from diabetics to contain fewer insulin receptors than placentas from nondiabetic gravidas. However, these studies were done using membrane fractions prepared from the placentas and at a time when adequacy of antepartum glycemic control in the diabetic patients was not routinely evaluated by self blood sugar measurement or hemoglobin A1 assay. The current study compares specific 125I-insulin binding in vitro to intact placental villi from 15 normal patients with insulin binding to intact villi obtained from 15 insulin-dependent diabetic mothers whose fasting and postprandial blood sugars and hemoglobin A1 levels were maintained in a range normal for term pregnancy. We demonstrate that insulin binding to intact placental villi is the same in this group of diabetic patients as in the nondiabetic patients.
The ability of 111In-PAY 276 (anti prostatic acid phosphatase antibody) in detecting pelvic lymph node metastasis following bipedal intra lymphatic administration was studied in five patients with carcinoma of the prostate. The labeled antibody was injected directly into the lymphatics of each foot. Planar and tomographic images radioactivity content of lymph nodes resected during staging pelvic lymphadenectomy were compared to the histologic and immunoperoxidase findings. Radioactivity in pelvic lymph nodes was prominently seen within 20 min of injection and was present 16 days later. Persistent accumulation of tracer in the lymphatics of the lower extremities was also observed in all patients 16 days post injection. Radioactivity counts in tumor-free lymph nodes were higher than in tumored lymph nodes resected. Our results demonstrate that intra lymphatic administration of 111In-labeled PAY 276 monoclonal antibody has major technical limitations, and that further research directed at the causes of tracer accumulation in the lymphatics and tumor-free lymph nodes is required.
We have evaluated the role of In-111 anti-CEA (carcinoembryonic antigen) monoclonal antibody ZCE 025 in 8 patients. Three patients had a confirmed diagnosis of gastric carcinoma. Three had a confirmed diagnosis of pancreatic carcinoma. Two patients had elevated serum levels of CEA with no known primary. Each patient received 5.5 mCi In-111 ZCE 025 infused at doses of 10-80 mg. Planar and single photon emission computed tomography (SPECT) imaging at 3 and 7 days after infusion detected 9 of 12 known tumor sites and all 5 of the previously identified sites of metastasis. In-111 ZCE 025 MoAb imaging also found 6 previously unsuspected tumor sites and changed the preoperative evaluation in 50% of the patients studied. It changed the clinical management in 2 patients and established the site of primary involvement in 2 others. There were no clinical or biochemical reactions. In-111 ZCE 025 monoclonal antibody scintigraphy is a useful adjunct in the evaluation of patients with either gastric or pancreatic carcinoma. It may have a beneficial impact on the surgical decision making in these patients.
The current study attempted to assess the potential proficiency of radioimmunodetection (RAID) of primary, residual, multicentric, and recurrent breast carcinoma using two radiolabeled murine monoclonal antibodies (MoAbs), anti-human milk fat globulin (HMFG1) labeled with iodine (123I) and anti-carcinoembryonic antigen (CEA) labeled with technetium (99Tc). Thirteen patients with suspicious clinical and/or mammographic primary or recurrent breast carcinoma were studied in a phase I-II prospective, consecutive, nonrandomized, noncontrolled study. Five patients received intravenous infusion with 0.5-2.0 mg anti-CEA MoAb type CYT 380 labeled with 99Tc [13-22 millicurie (mCI)] and 8 patients received intravenous infusion with 0.25-1.0 mg anti-HMFG1 MoAb (Unipath, U.K.) labeled with 123I (4-17 mCI). Both MoAbs used in this study demonstrated ability to bind specifically to breast cancer lesions, resulting in successful RAID in 10 of 12 of studied patients (5 of 5 patients in the anti-CEA-99Tc and 5 of 7 in the anti-HMFG-123I group--accuracy 83.3%). One patient was excluded due to protocol violation. Seven patients had true-positive scans when correlated with surgery (sensitivity 87.5%). The MoAb scans accurately diagnosed lesions in 3 of the 4 primary invasive breast carcinomas confirmed histologically. Presence of residual carcinoma following wide excision was established in 1 of 2 patients and presence of soft tissue metastases in 3 patients. Three patients had true-negative scan (specificity 75%): 2 patients presented with suspicious mammographic recurrence postlumpectomy and 1 patient had questionable soft tissue recurrence. One patient with primary breast carcinoma had a false-negative scan and another had a false-positive scan in the presence of fibrosis following lumpectomy and radiation therapy. No adverse reactions were noted in the patients studied. RAID findings were confirmed by immunohistochemistry in 6 of 9 cases studied. Our data suggest that radiolabeled MoAbs used in this study are potentially useful diagnostic agents for evaluation of primary or recurrent breast carcinoma, particularly in the areas where conventional methodology is limited.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.