Understanding the factors that affect the occurrence of failures in urban drainage networks (UDNs) is a key concept for developing strategies to improve the reliability of such systems. Although a lot of research has been done in this field, the relationship between UDN structure (i.e. layout) and its functional failures is still unclear. In this context, the present study focuses first on determining which are the most common sewer layout topologies, based on a data set of 118 UDNs, and then on analyzing the relationship between these and the occurrence of node flooding using eight subnetworks of the sewer system of Dresden, Germany, as a study case. A method to ‘quantify’ the topology of a UDN in terms of similarity to a branched or meshed system, referred to as Meshness, is introduced. Results indicate, on the one hand, that most networks have branched or predominantly branched topologies. On the other hand, node flooding events in networks with higher Meshness values are less likely to occur, and have shorter durations and smaller volumes than in predominantly branched systems. Predominantly meshed systems are identified then as more reliable in terms of flooded nodes and flooding volumes.
As environmental change is happening at an unprecedented pace, a reliable and proper urban drainage design is required to alleviate the negative effects of unexpected extreme rainfall events occurring due to the natural and anthropogenic variations such as climate change and urbanization. Since structure/configuration of a stormwater network plays an imperative role in the design and hydraulic behavior of the system, the goal of this paper is to elaborate upon the significance of possessing redundancy (e.g., alternative flow paths as in loops) under simultaneous hydraulic design in stormwater pipe networks. In this work, an innovative approach based on complex network properties is introduced to systematically and successively reduce the number of loops and, therefore, the level of redundancy, from a given grid-like (street) network. A methodology based on hydrodynamic modelling is utilized to find the optimal design costs for all created structures while satisfying a number of hydraulic design constraints. As a general implication, when structures are subject to extreme precipitation events, the overall capability of looped configurations for discharging runoff more efficiently is higher compared to more branched ones. The reason is due to prevailing (additional) storage volume in the system and existing more alternative water flow paths in looped structures, as opposed to the branched ones in which only unique pathways for discharging peak runoff exist. However, the question arises where to best introduce extra paths in the network? By systematically addressing this question with complex network analysis, the influence of downstream loops was identified to be more significant than that of upstream loops. Findings, additionally, indicated that possessing loop and introducing extra capacity without determining appropriate additional pipes positions in the system (flow direction) can even exacerbate the efficiency of water discharge. Considering a reasonable and cost-effective budget, it would, therefore, be worthwhile to install loop-tree-integrated stormwater collection systems with additional pipes at specific locations, especially downstream, to boost the hydraulic reliability and minimize the damage imposed by the surface flooding upon the metropolitan area.
Combined sewer overflows (CSOs) prevent surges in sewer networks by releasing untreated wastewater into nearby water bodies during intense storm events. CSOs can have acute and detrimental impacts on the environment and thus need to be managed. Although several gray, green and hybrid CSO mitigation measures have been studied, the influence of network structure on CSO occurrence is not yet systematically evaluated. This study focuses on evaluating how the variation of urban drainage network structure affects the frequency and magnitude of CSO events. As a study case, a sewer subnetwork in Dresden, Germany, where 11 CSOs are present, was selected. Scenarios corresponding to the structures with the lowest and with the highest number of possible connected pipes, are developed and evaluated using long-term hydrodynamic simulation. Results indicate that more meshed structures are associated to a decrease on the occurrence and magnitude of CSO. Event frequency reductions vary between 0% and 68%, while reduction of annual mean volumes and annual mean loads ranged between 0% and 87% and 0% and 92%. These rates were mainly related to the additional sewer storage capacity provided in the more meshed scenarios, following a sigmoidal behavior. However, increasing network connections causes investment costs, therefore optimization strategies for selecting intervention areas are needed. Furthermore, the present approach of reducing CSO frequency may provide a new gray solution that can be integrated in the development of hybrid mitigation strategies for the CSO management.
The objective of this research is to evaluate whether complex dynamics of urban drainage networks (UDNs) can be expressed in terms of their structure, i.e. topological characteristics. The present study focuses on the application of topological measures for describing the transport and collection functions of UDNs, using eight subnetworks of the Dresden sewer network as study cases. All UDNs are considered as weighted directed graphs, where edge weights correspond to structural and hydraulic pipe characteristics which affect flow. Transport functions are evaluated in terms of travel time distributions (TTDs), under the hypothesis that frequency distributions of Single Destination Shortest Paths (SDSP) of nodes to the outlet had similar shapes than TTDs. Assessment of this hypothesis is done based on two-sample Kolmogorov-Smirnov tests and comparisons of statistical moments. Collection analysis, i.e. determination of flow paths, is done based on two approaches: (1) using Edge Betweenness Centrality (EBC), and (2) based on the number of SDSP going through an edge connecting a node to the outlet, referred as Paths. Hydrodynamic simulation results are used to validate the outcomes of graph analysis with actual flow behaviors. Results indicate that given an appropriate edge weighting factor, in this case Residence Time, SDSP has the potential to be used as an indicator for flow transport in UDNs. Moreover, both EBC and Paths values were highly correlated to average flows. The first approach, however, proved to be inadequate for estimating flows near the outlet but appropriate for identifying different paths in meshed systems, while the second approach lead to better results in branched networks. Further studies regarding the influence of UDNs layout are needed.
Water and pollutant fluxes from combined sewer overflows (CSO) have a significant impact on receiving waters. The random nature of rainfall forcing dominates the variability of sewer discharges, pollutant loads, and concentrations. An analytical model developed here shows how sewer network topology and rainfall properties variously impact the stochasticity of CSO functioning. Probability distributions of sewer discharge and concentration compare well with the results from a calibrated Storm Water Management Model in an application to a sewershed located in Dresden, Germany. The model is determined by only four parameters, three of which can be predicted a priori, two from the rainfall record and one from the network topology using geomorphological flow recession theory, while the fourth can be estimated from a short discharge time series. The sensitivity of CSO and wastewater treatment loads to network structure suggests simple topologies may be more vulnerable to poor performance. The analytical model is useful for evaluating various CSO management strategies to reduce adverse impacts on receiving waters in a probabilistic setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.