Objective:The purpose of this study was to assess the microhardness of posterior composite resins at different depths varying the post-irradiation time.Materials and methods:For each composite resin [Solitaire 2 (SO) - Heraus Kulzer, P60 (P) - 3M, Prodigy Condesable (PC) - Kerr, Surefil (S) - Dentsply and Alert (A) - Pentron], 6 specimens (3 mm in diameter; 4mm high) were prepared using a black polyurethane cylindrical matrix. The resins were inserted in a bulk increment and light cured for 40 seconds. Microhardness was analyzed at different depths (top, 0.4 mm, 1.0 mm, 2.0mm, 3.0 mm and 4.0 mm) and at two moments (20 minutes and 24 hours after light-curing). Data were analyzed by ANOVA and Tukey's test (p<0.05).Results:Overall, microhardness means decreased significantly with the increase of depth, being lower in the first moment tested. P, S and PC showed the highest microhardness means.Conclusion:It may be concluded that the tested composite resins presented a gradual decrease of microhardness as depth increased and this drop was more accentuated for depths beyond 2 mm. For all materials, higher microhardness means were recorded 24 hours after light activation. P60 yielded the best results at the different depths evaluated.
The aim of this study was to assess the tensile bond strength of four adhesive systems to enamel and dentin: Clearfil Liner Bond 2V -C, Prime&Bond NT/NRC -PB, Single Bond -SB and All Bond 2 -AB. For such purpose, 40 sound human molars were selected. Crowns were bisected in a mesiodistal direction and each half was ground until flat enamel (E) or dentin (D) surfaces were obtained. A total of 80 specimens were randomly assigned to 4 groups (n=20, 10 in enamel and 10 in dentin). After surface treatment, a composite resin (Z250; 3M) cone was prepared using a split Teflon ® matrix. Bond strength was tested in an universal testing machine (0. . Statistical analysis of data by two-way ANOVA showed that C presented the best results followed by SB. In conclusion, among the tested materials, Clearfil Liner Bond 2V self-etching primer adhesive syetem had the best performance. The substrate type influenced bond strength, being higher to enamel.
The aim of the present study was to evaluate the influence of different photopolymerization (halogen, halogen soft-start and LED) systems on shear bond strength (SBS) and marginal microleakage of composite resin restorations. Forty Class V cavities (enamel and dentin margins) were prepared for microleakage assessment, and 160 enamel and dentin fragments were prepared for the SBS test, and divided into 4 groups. Kruskal-Wallis and Wilcoxon tests showed statistically significant difference in microleakage between the margins (p < 0.01) with incisal margins presenting the lowest values. Among the groups, it was observed that, only at the cervical margin, halogen soft-start photo polymerization presented statistically significant higher microleakage values. For SBS test, ANOVA showed no statistical difference (p > 0.05) neither between substrates nor among groups. It was concluded that Soft-Start technique with high intensity end-light influenced negatively the cervical marginal sealing, but the light-curing systems did not influence adhesion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.