A: Recently, high-energy radiation has been widely used in various industrial fields, including the medical industry, and increasing research efforts have been devoted to the development of radiation detectors to be used with high-energy radiation. In particular, nondestructive industrial applications use high-energy radiation for ships and multilayered objects for accurate inspection. Therefore, it is crucial to verify the accuracy of radiation dose measurements and evaluate the precision and reproducibility of the radiation output dose. Representative detectors currently used for detecting the dose in high-energy regions include Si diodes, diamond diodes, and ionization chambers. However, the process of preparing these detectors is complex in addition to the processes of conducting dosimetric measurements, analysis, and evaluation. Furthermore, the minimum size that can be prepared for a detector is limited. In the present study, the disadvantages of original detectors are compensated by the development of a detector made of a mixture of polycrystalline PbI 2 and PbO powder, which are both excellent semiconducting materials suitable for detecting high-energy gamma rays and X-rays. The proposed detector shows characteristics of excellent reproducibility and stable signal detection in response to the changes in energy, and was analyzed for its applicability. Moreover, the detector was prepared through a simple process of particle-in-binder 1Corresponding author.
Lately, cancer has been treated using high-energy radiation, and this requires highly reliable treatment plans. Therefore, a dosimeter with excellent performance, which is capable of precise dose measurement, is critical. In current clinical practices, an ionization chamber and diode utilizing the ionization reaction mechanism are widely used. Several studies have been carried out to determine optimal materials for the detector in a dosimeter to enable diagnostic imaging. Recently, studies with lead monoxide, which was shown to have low drift current and high resolving power at a high bias, were reported with the dosimeter exhibiting a fast response time against incident photons. This research aims to investigate the feasibility of a lead monoxide-based dosimeter for QA (quality assurance) in radiotherapy. In this paper, we report that the manufactured dosimeter shows similar linearity to a silicon diode and demonstrates similar characteristics in terms of PDD (percent depth dose) results for the thimble ionization chamber. Based on these results, it is demonstrated that the lead monoxide-based dosimeter complies with radiotherapy QA requirements, namely rapid response time, dose linearity, dose rate independence. Thus, we expect the lead monoxide-based dosimeter to be used commercially in the future.
A: Imaging technology based on gamma-ray sources has been extensively used in nondestructive testing (NDT) to detect any possible internal defects in products without changing their shapes or functions. However, such technology has been subject to increasingly stricter regulations, and an international radiation-safety management system has been recently established. Consequently, radiation source location in NDT systems has become an essential process, given that it can prevent radiation accidents. In this study, we focused on developing a monitoring system that can detect, in real time, the position of a radioactive source in the source guide tube of a projector. We fabricated a lead iodide (PbI 2 ) dosimeter based on the particle-in-binder method, which has a high production yield and facilitates thickness and shape adjustment. Using a gamma-ray source, we then tested the reproducibility, linearity of the dosimeter response, and the dosimeter's percentage interval distance (PID). It was found that the fabricated PbI 2 dosimeter yields highly accurate, reproducible, and linear dose measurements. The PID analysis -conducted to investigate the possibility of developing a monitoring system based on the proposed dosimeterindicated that the valid detection distance was approximately 11.3 cm. The results of this study are expected to contribute to the development of an easily usable radiation monitoring system capable of significantly reducing the risk of radiation accidents. K: Dosimetry concepts and apparatus; Radiation monitoring; Inspection with gamma rays; Materials for solid-state detectors 1Corresponding author.
A: With the recent market entries of new types of linear accelerators (LINACs) with a multi leaf collimator (MLC) mounted on them, high-precision radiosurgery applying a LINAC to measure high-dose radiation on the target region has been gaining popularity. Systematic and accurate quality assurance (QA) is of vital important for high-precision radiosurgery because of its increased risk of side effects including life-threatening ones such as overexposure of healthy tissues to highdose radiation beams concentrated on small areas. Therefore, accurate dose and dose-distribution measurements are crucial in the treatment procedure. The accurate measurement of the properties of beams concentrated on small areas requires high-precision dosimeters capable of high-resolution output and dose mapping as well as accurate dosimetry in penumbra regions. In general, the properties of beams concentrated on small areas are measured using thermos luminescent dosimeters (TLD), diode detectors, ion chambers, diamond detectors, or films, and many papers have presented the advantages and disadvantages of each of these detectors for dosimetry. In this study, a solid-state photoconductor dosimeter was developed, and its clinical usability was tested by comparing its relative dosimetric performance with that of a conventional ion chamber. As materials best-suited for radiation dosimeters, four candidates namely lead (II) iodide (PbI 2 ), lead (II) oxide (PbO), mercury (II) iodide (HgI 2 ), and HgI 2 / titanium dioxide (TiO 2 ) composite, the performances of which were proved in previous studies, were used. The electrical properties of each candidate material were examined using the sedimentation method, one of the particle-in-binder (PIB) methods, and unit-celltype prototypes were fabricated. The unit-cell samples thus prepared were cut into specimens of area 1 × 1 cm 2 with 400-µm thickness. The electrical properties of each sample, such as sensitivity, dark current, output current, rising time, falling time, and response delay, were then measured, in addition to the consistency, reproducibility and linearity of each unit-cell. According to the measurement results, HgI 2 /TiO 2 composite outperformed the other candidate materials. A radiation dosimeter with a chamber-type structure was fabricated in this study using a LINAC under accelerating voltages of 6, and 15 MV and compared with a commercial ion chamber. Percent depth dose (PDD) and beam profile were measured on a water phantom at a fixed area of 10 × 10 cm 2 by using the fabricated chamber-type dosimeter, and the values were compared with those measured by a commercial ion chamber. Additionally, a homogeneous phantom was fabricated, and the exposure doses of the center points were measured according to a real treatment plan, followed by a comparison of the measured values as relative values. In this paper, we report that the manufactured dosimeter shows similar characteristics in terms of PDD and beam profile and results for the conventional ion chamber. Based on these results, it ...
A: The most widely used form of radiotherapy to treat tumors uses a linear accelerator, and the apparatus requires regular quality assurance (QA). QA for a linear accelerator demands accuracy throughout, from mock treatment and treatment planning, up to treatment itself. Therefore, verifying a radiation dose is essential to ensure that the radiation is being applied as planned. In current clinical practice, ionization chambers and diodes are used for QA. However, using conventional gaseous ionization chambers presents drawbacks such as complex analytical procedures, difficult measurement procedures, and slow response time. In this study, we discuss the potential of a lead(II) iodide (PbI 2 )-based radiation dosimeter for radiotherapy QA. PbI 2 is a semiconductor material suited to measurements of X-rays and gamma rays, because of its excellent response properties to radiation signals. Our results show that the PbI 2 -based dosimeter offers outstanding linearity and reproducibility, as well as dose-independent characteristics. In addition, percentage depth dose (PDD) measurements indicate that the error at a fixed reference depth D max was 0.3%, very similar to the measurement results obtained using ionization chambers. Based on these results, we confirm that the PbI 2 -based dosimeter has all the properties required for radiotherapy: stable dose detection, dose linearity, and rapid response time. Based on the evidence of this experimental verification, we believe that the PbI 2 -based dosimeter could be used commercially in various fields for precise measurements of radiation doses in the human body and for measuring the dose required for stereotactic radiosurgery or localized radiosurgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.