We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch.
This paper proposes and tests a design of electro-thermal bimorph actuators for alignment of flexible photonic waveguides fabricated in 16 µm thick SiO 2 . The actuators are for use in a novel alignment concept for multi-port photonic integrated circuits (PICs), in which the fine alignment is taken care of by positioning of suspended, mechanically flexible waveguide beams on one or more of the PICs. The design parameters of the bimorph actuator allow to tune both the initial relative position of the waveguide end-facets, and the motion range of the actuators. Bimorph actuators have been fabricated and characterized. The maximum out-of-plane deflection of the bimorph actuator (with 720 µm-long poly-Si) can reach 18.5 µm with 126.42 mW, sufficient for the proposed application.
Fully automated, high precision, cost-effective assembly technology for photonic packages remains one of the main challenges in photonic component manufacturing. Next to the cost aspect the most demanding assembly task for multiport photonic integrated circuits (PICs) is the high-precision (±0.1 μm) alignment and fixing required for optical I/O in InP PICs, even with waveguide spot size conversion. In a European research initiative -PHASTFlex -we develop and investigate an innovative, novel assembly concept, in which the waveguides in a matching TriPleX interposer PIC are released during fabrication to make them movable. After assembly of both chips by flip-chip bonding on a common carrier, TriPleX based actuators and clamping functions position and fix the flexible waveguides with the required accuracy.
Photonic packaging, which includes high-precision assembly of photonic sub-systems, is currently a bottleneck in the development of commercially-available integrated photonic products. In the pursuit of a fully-automated, high-precision, and cost-effective photonic alignment scheme for two multi-channel photonic chips, this paper explores different designs of the on-chip electrothermal actuators for positioning mechanically-flexible waveguide structures. The final alignment goal is ∼100 nm waveguide to waveguide. The on-chip actuators, particularly for out-of-plane actuation, are built in a 16 μm-thick SiO2 photonic-material stack with 5 μm-thick poly-Si as an electrothermal element. A major challenge of out-of-plane positioning is a 6 μm height difference of the waveguides to be aligned, due to different built-up material stacks, together with a misalignment tolerance of 1 μm–2 μm from the pre-assembly (flip-chip) process. Therefore, the bimorph-actuator design needs to compensate this height difference, and provide sufficient motion to align the waveguides. We propose to exploit the post-release deformation of so-called short-loop bimorph actuator designs to meet these joint demands. We explore different design variants based on the heater location and the integration of actuator beams with waveguide beams. The actuator design (with 30 μm poly-Si and 900 μm SiO2 in length) has ∼8 μm out-of-plane deflection and is able to generate ∼4 μm motion, which meets the design goal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.