Background South Africa was the African country with the most recorded cases of SARS-CoV-2 during 2020, experiencing 2 waves of infection. During the first wave, diagnostics were largely based on reverse transcription-linked PCR (RT-PCR). The Abbott PanBio antigen test was deployed during the 2nd wave which may have been driven by emergence of the B.1.351 variant. At the time of evaluation in mid-November 2020, B.1.351 was the dominant circulating virus in Nelson Mandela Bay, in the Eastern Cape Province. Methods Used PanBio antigen swabs (collected from patients with genetically characterised virus) were first validated as suitable for PCR. A prospective study was then undertaken to evaluate assay performance in the field. Testing was conducted at mobile community testing centres on 677 ambulant patients. Used swabs were kept and tested by RT-PCR. Results During initial validation, used swabs in proprietary lysis buffer were found to be suitable for PCR and secondly, the PB assay reliably detected patients infected with B.1.351. In the field study, of 146 RT-PCR positive individuals, 101 were RTD positive in the clinic. The RTD had a sensitivity of 69.2% (95%CI 61.4, 75.8) and specificity of 99.0% (95%CI 98.8, 99.3). Sensitivity was dependent on the amount of viral RNA in clinical samples, as reflected by the PCR cycle threshold (CT) value. Conclusions The assay reliably detected B.1.351 infections in ambulatory ill patients during initial validation and in field testing. In the field, assay sensitivity was >90% in patients with high viral loads who are expected to be most infectious. Negative and positive predictive values were also >90%.
Background: South Africa was the African country most severely affected by the SARS-CoV-2 pandemic during 2020, experiencing 2 waves of infection. During the first wave, diagnostics were largely based on reverse transcription-linked PCR (RT-PCR). The Abbott PanBio antigen test was deployed during the 2nd wave which was driven by emergence of the 501Y.v2 variant. At the time of evaluation in mid-November 2020, 501Y.v2 was the dominant circulating virus in Nelson Mandela Bay, in the Eastern Cape Province. Methods: A prospective diagnostic evaluation study was undertaken, during a period of high community transmission, to evaluate the field performance of the PanBio antigen RTD. Testing was conducted at mobile community testing centres on 677 ambulant patients seeking SARS-CoV-2 testing. RT-PCR was performed on the original naso-pharyngeal antigen swabs to evaluate test performance. Results: Of 146 RT-PCR positive individuals, 101 were RTD positive in the clinic. The antigen RTD had an overall sensitivity of 69.2% (95%CI 61.4, 75.8) and specificity of 99.0% (95%CI 98.8, 99.3) in this clinical context. Sensitivity was strongly dependent on the amount of virus in clinical samples, as reflected by the PCR cycle threshold (CT) value, with 100% detection in samples where the CT was <20, 96% with CT between 20-25, 89% with CT between 26-30 and 64% when CT was 31-35. Conclusions: The assay reliably detected 501Y.v2 infections in ambulatory ill patients. Assay sensitivity was >90% in patients with high viral loads who are expected to be most infectious. Negative and positive predictive values were also >90%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.