We report on an adjustable interferometric set-up for Scanning Microwave Microscopy. This interferometer is designed in order to combine simplicity, a relatively flexible choice of the frequency of interference used for measurements as well as the choice of impedances range where the interference occurs. A vectorial calibration method based on a modified 1-port error model is also proposed. Calibrated measurements of capacitors have been obtained around the test frequency of 3.5 GHz down to about 0.1 fF. Comparison with standard vector network analyzer measurements is shown to assess the performance of the proposed system.
We give an analytical and experimental demonstration of a classical analogue of the electromagnetic induced absorption (EIA) in a simple photonic device consisting of two stubs of lengths d1 and d2 grafted at the same site along a waveguide. By detuning the lengths of the two stubs (i.e. δ = d(2) - d(1)) we show that: (i) the amplitudes of the electromagnetic waves in the two stubs can be written following the two resonators model where each stub plays the role of a radiative resonator with low Q factor. The destructive interference between the waves in the two stubs may give rise to a sharp resonance peak with high Q factor in the transmission as well as in the absorption. (ii) The transmission coefficient around the resonance induced by the stubs can be written following a Fano-like form. In particular, we give an explicit expression of the position, width and Fano parameter of the resonances as a function of δ. (iii) By taking into account the loss in the waveguides, we show that at the transmission resonance, the transmission (reflection) increases (decreases) as a function of δ. Whereas the absorption goes through a maximum around 0.5 for a threshold value δth which depends on the attenuation in the system and then falls to zero. (iv) We give a comparison between the phase of the determinant of the scattering matrix, the so-called Friedel phase and the phase of the transmission amplitude. (v) The effect of the boundary conditions at the end of the resonators on the EIA resonance is also discussed. The analytical results are obtained by means of the Green's function method, whereas the experiments are carried out using coaxial cables in the radio-frequency regime. These results should have important consequences for designing integrated devices such as narrow-frequency optical or microwave filters and high-speed switches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.