The medial collateral ligament (MCL) of the rabbit left hindlimb was ruptured by a rod placed beneath it, resulting in a "mop-end" tear of the ligament substance with simultaneous injury to the insertion sites. Using this model, we compared primary ligament repair and nonoperative treatment using biomechanical and histologic techniques at time zero, 10 days, and 6 and 12 weeks postoperatively. Biomechanical evaluation included measurement of varus-valgus (V-V) knee rotation, in situ load on the MCL, and tensile testing of the femur-MCL-tibia complex (FMTC). The V-V rotation of all experimental knees decreased over time. At 12 weeks, V-V rotation of experimental knees was still 1.3 times larger than that of controls. Primary repair initially decreased V-V rotation, but at 6 and 12 weeks there was no statistical difference between operated and nonoperated knees. The in situ load on the MCL followed the same trends. There was no significant effect of MCL repair on any of the tensile properties. However, postoperative healing time significantly improved the FMTC structural properties in both experimental groups. Failure modes of the FMTCs and histologic sections of the ligament insertion sites indicated that after injury the ligament insertion to bone recovered more slowly than the ligament substance. Tensile testing of the FMTC showed that even at 12 weeks postoperatively the mechanical properties of the healed ligament material remained significantly different from those of the controls.
The effects of strain rate on the structural properties of the femur-medial collateral ligament-tibia complex (FMTC) and on the mechanical (material) properties of the medial collateral ligament (MCL) of skeletally immature and skeletally mature rabbits were studied. The FMTCs were tested in tension to failure, at five extension rates (0.008 mm/s-113 mm/s). For the FMTCs from the skeletally immature animals, values of load, elongation, and energy absorbed at failure increased substantially with extension rates. Such increases also existed for skeletally mature animals, but they were much less in magnitude. All samples from the skeletally immature animals failed by tibial avulsion, whereas samples from the skeletally mature animals failed within the ligament substance. The mechanical properties of the ligament substance were minimally strain-rate sensitive for both groups. Histological sections of the ligament substance and insertion sites from the failed samples were examined, and these observations were correlated with the biomechanical findings. For the rabbit model used in this study, we conclude that skeletal maturity has more influence on the biomechanical properties of the MCL than does strain rate.
Determination of the tensile stresses in ligaments and tendons during uniaxial loading depends on accurate measurement of the cross-sectional area. In this study, a laser micrometer system was employed to evaluate the cross-sectional shape and area of the medial collateral ligament (MCL) at three locations and anterior cruciate ligament (ACL). In a New Zealand White (NZW) rabbit, morphologic sections of the ligaments were made to verify the cross-sectional shape reconstructed by the laser micrometer system. The areas obtained by the laser micrometer system from ten additional NZW rabbits were compared with those obtained by two other methods commonly used to measure the cross-sectional area of ligaments and tendons: one method uses digital calipers and the other a constant pressure (0.12 MPa) area micrometer. For the MCL, the digital calipers yielded results very similar to those of the laser micrometer, but the constant pressure area micrometer yielded values 20 percent lower. The area measured at the proximal site of the MCL was 13 percent greater than the area measured at the joint line and distal line. For the ACL, the values obtained by the digital calipers and constant pressure area micrometer were 16 and 20 percent lower, respectively. Because of the irregular shape exhibited by the rabbit ACL, the digital calipers could not accurately measure the cross-sectional area. The constant pressure area micrometer yielded lower values for the cross-sectional area of both the MCL and ACL, presumably due to the applied pressure which caused changes in both the cross-sectional shape and area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.