Heat recovery from a flue gas stream by cooling and condensation in a packed bed column is widely used to increase plant's energy efficiency. Mass transfer equipment manufacturers have the possibility to optimize the size of such cooling towers and therefore its derived investment costs through selection of best suitable mass/heat transfer components. In this work, a real industrial design case of a cooling-condensing tower equipped with different high capacity random and structured packings is presented. The impact of the selected packings on tower dimensions and investment costs is evaluated and discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.