We developed nanoparticles with tailored magnetic properties for direct and sensitive detection of biomolecules in biological samples in a single step. Thermally blocked nanoparticles obtained by thermal hydrolysis, functionalized with specific ligands, are mixed with sample solutions, and the variation of the magnetic relaxation due to surface binding is used to detect the presence of biomolecules. The binding significantly increases the hydrodynamic volume of nanoparticles, thus changing their Brownian relaxation frequency which is measured by a specifically developed AC susceptometer. The system was tested for the presence of Brucella antibodies, a dangerous pathogen causing brucellosis with severe effects both on humans and animals, in serum samples from infected cows and the surface of the nanoparticles was functionalized with lipopolysaccharides (LPS) from Brucella abortus. The hydrodynamic volume of LPS-functionalized particles increased by 25-35% as a result of the binding of the antibodies, measured by changes in the susceptibility in an alternating magnetic field. The method has shown high sensitivity, with detection limit of 0.05 microg x mL(-1) of antibody in the biological samples without any pretreatment. This magnetic-based assay is very sensitive, cost-efficient, and versatile, giving a direct indication whether the animal is infected or not, making it suitable for point-of-care applications. The functionalization of tailored magnetic nanoparticles can be modified to suit numerous homogeneous assays for a wide range of applications.
Using magnetic particles with sizes in the nanometer range in biomedical magnetic separation has gained much interest recently due to their higher surface area to particle volume and lower sedimentation rates. In this paper, we report our both theoretical and experimental investigation of the motion of magnetic particles in a magnetic field gradient with particle sizes from 425 nm down to 50 nm. In the experimental measurements, we monitor the absorbance change of the sample volume as the particle concentration varies over time. We also implement a Brownian dynamics algorithm to investigate the influence of particle interactions during the separation and compare it to the experimental results for validation. The simulation agrees well with the measurements for particle sizes around 425 nm. Some discrepancies remain for smaller particle sizes, which may indicate that additional factors also influence the separation for the smaller size range. We observe that the separation process includes the formation of chainlike particle aggregates due to the magnetic dipole-dipole interactions between particles when subjected to an external magnetic field. We can also see that the hydrodynamic interaction between these chains contributes to reducing the separation time. In conclusion, we show that the formation of these particle aggregates, and to a less extent the hydrodynamic interactions between them contributes to significantly enhancing the particle separation process.
With today's developments of biosensors and medical implants comes the need for efficient reduction of nonspecific binding. We report on a comparison of the ability of traditionally used blocking agents and poly(ethylene glycol) (PEG) derivatives to prevent protein adsorption on both gold and polystyrene surfaces. The adsorption kinetics of blocking molecules and proteins was monitored gravimetrically using quartz crystal microbalance with dissipation (QCM-D). The resistance to nonspecific adsorption was evaluated on gold and polystyrene surfaces coated with bovine serum albumin (BSA) or casein, gold coated with three different 6-11 ethylene glycol (EG) long hydroxyl- or methoxy-terminated PEG-thiolates and polystyrene blocked with a PLL-g-PEG or three different 12 EG long benzyl-PEG-derivatives. The prevention of protein adsorption on the coated surfaces was evaluated by monitoring the mass uptake at the addition of both pure prostate specific antigen (PSA) and seminal plasma. We demonstrate that on pure gold the PEG-thiols are superior to the other blocking molecules tested, with the end group and length of the PEG-thiols used being of minor importance. On polystyrene surfaces blocking with PLL-g-PEG, BSA and casein gave the best results. These results have an impact on further development of an optimized immunoassay protocol.
Inactivation of 4 microorganisms in orange juice was investigated in a 100 L/h flowing pulsed electric field (PEF) system. Electric field levels of 30 kV/cm and 50 kV/cm were applied, and Leuconostoc mesenteroides, E. coli, and Listeria innocua were inactivated by as much as 5 log cycles at 30 kV/cm and 50°C. Saccharomyces cerevisiae ascospores were the least susceptible to PEF at all treatment levels, and a maximum of 2.5 log reduction was achieved at 50 kV/cm and 50°C. Both electric field levels were effective in inactivating microorganisms at temperatures below standard thermal treatment, however, the number of pulses applied was particularly important in inactivation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.