Background Correct positioning of pedicle screws can be challenging. Intraoperative imaging may be helpful. The purpose of this study was to evaluate the use of intraoperative 3D imaging with a cone-beam CT. The hypotheses were that intraoperative 3D imaging (1) will lead to an intraoperative revision of pedicle screws and (2) may diminish the rate of perforated screws on postoperative imaging. Methods Totally, 351 patients (age 60.9 ± 20.3 a (15–96); m/f 203/148) underwent dorsal instrumentation with intraoperative 3D imaging with 2215 pedicle screws at a trauma center level one. This study first evaluates intraoperative imaging. After this, 501 screws in 73 patients (age 62.5 ± 19.7 a; m/f 47/26) of this collective were included in the study group (SG) and their postoperative computed tomography was evaluated with regard to screw position. Then, 500 screws in 82 patients (age 64.8 ± 14.4 a; m/f 51/31) as control group (CG), who received the screws with conventional 2D fluoroscopy but without 3D imaging, were evaluated with regard to screw position. Results During the placement of the 2215 pedicle screws, 158 (7.0%) intraoperative revisions occurred as a result of 3D imaging. Postoperative computed tomography of the SG showed 445 (88.8%) screws without relevant perforation (type A + B), of which 410 (81.8%) could be classified as type A and 35 (7.0%) could be classified as type B. Fifty-six (11.2%) screws in SG showed relevant perforation (type C–E). In contrast, 384 (76.8%) screws in the CG were without relevant perforation (type A + B), of which 282 (56.4%) could be classified as type A and 102 (20.4%) as type B. One hundred and sixteen (23.2%) screws in the CG showed relevant perforation (type C–E). Conclusion This study shows that correct placement of pedicle screws in spine surgery with conventional 2D fluoroscopy is challenging. Misplacement of screws cannot always be prevented. Intraoperative 3D imaging with a CBCT can be helpful to detect and revise misplaced pedicle screws intraoperatively. The use of intraoperative 3D imaging will probably minimize the number of revision procedures due to perforating pedicle screws.
Background Intraoperative cone beam CT (CBCT) imaging in dorsal instrumentation facilitates pedicle screw positioning. However, in patients with obesity, the benefit may be reduced due to artifacts that affect image quality. The purpose of this study was to evaluate whether intraoperative CBCT leads to an improved postoperative screw position compared to conventional fluoroscopy independent of body weight. Methods A total of 71 patients (18 patients with a BMI > 30 kg/m2, 53 patients with a BMI < 30 kg/m2) who underwent dorsal instrumentation with intraoperative CBCT imaging were included in study groups one (SG1) and two (SG2). Two control groups (CG1 and CG2) were randomly sampled to include 22 patients with a BMI > 30 kg/m2 and 60 patients with a BMI < 30 kg/m2 who underwent dorsal instrumentation without intraoperative CBCT imaging. The pedicle screw position in postoperative computed tomography was assessed using the Gertzbein–Robbins classification. Results In SG1 (BMI > 30 kg/m2), a total of 107 (83.6%) pedicle screws showed no relevant perforation (type A + B), and 21 (16.4%) pedicle screws showed relevant perforation (type C − E). In SG2 (BMI < 30 kg/m2), 328 (90.9%) screws were classified as type A + B, and 33 (9.1%) screws were classified as type C − E. In CG1 (BMI > 30 kg/m2), 102 (76.1%) pedicle screws showed no relevant perforation (type A + B), and 32 (23.9%) pedicle screws showed relevant perforation (type C − E). In CG2 (BMI < 30 kg/m2), 279 (76.9%) screws were classified as type A + B, and 84 (23.1%) screws were classified as type C − E. There were significant differences between the values of SG1 and SG2 (p = 0.03) and between the values of SG2 and CG2 (p < 0.0001). Conclusion CBCT imaging in dorsal instrumentation can lead to an improved pedicle screw position among both patients with obesity and normal-weight patients. However, patients with obesity showed significantly worse pedicle screw positions postoperatively after dorsal instrumentation with intraoperative CBCT imaging than normal-weight patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.