Highly dispersed iron-based quantum dots (QDs) onto powdered Vulcan XC-72R substrate were successfully electrodeposited by the rotating disk slurry electrodeposition (RoDSE) technique. Our findings through chemical physics characterization revealed that the continuous electron pathway interaction between the interface metal–carbon is controlled. The rotating ring-disk electrode (RRDE) and the prototype generation unit (PGU) of in-situ H2O2 generation in fuel cell experiments revealed a high activity for the oxygen reduction reaction (ORR) via two-electron pathway. These results establish the Fe/Vulcan catalyst at a competitive level for space and terrestrial new materials carriers, specifically for the in-situ H2O2 production. Transmission electron microscopy (TEM) analysis reveals the well-dispersed Fe-based quantum dots with a particle size of 4 nm. The structural and chemical-physical characterization through induced coupled plasma-optical emission spectroscopy (ICP-OES), transmission scanning electron microscopy (STEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and X-ray absorption spectroscopy (XAS); reveals that, under atmospheric conditions, our quantum dots system is a Fe2+/3+/Fe3+ combination. The QDs oxidation state tunability was showed by the applied potential. The obtention of H2O2 under the compatibility conditions of the drinking water resources available in the International Space Station (ISS) enhances the applicability of this iron- and carbon-based materials for in-situ H2O2 production in future space scenarios. Terrestrial and space abundance of iron and carbon, combined with its low toxicity and high stability, consolidates this present work to be further extended for the large-scale production of Fe-based nanoparticles for several applications.
Near-infrared (NIR) spectroscopy is a promising technique for field identification of substandard and falsified drugs because it is portable, rapid, nondestructive, and can differentiate many formulated pharmaceutical products. Portable NIR spectrometers rely heavily on chemometric analyses based on libraries of NIR spectra from authentic pharmaceutical samples. However, it is difficult to build comprehensive product libraries in many low- and middle-income countries due to the large numbers of manufacturers who supply these markets, frequent unreported changes in materials sourcing and product formulation by the manufacturers, and general lack of cooperation in providing authentic samples. In this work, we show that a simple library of lab-formulated binary mixtures of an active pharmaceutical ingredient (API) with two diluents gave good performance on field screening tasks, such as discriminating substandard and falsified formulations of the API. Six data analysis models, including principal component analysis and support-vector machine classification and regression methods and convolutional neural networks, were trained on binary mixtures of acetaminophen with either lactose or ascorbic acid. While the models all performed strongly in cross-validation (on formulations similar to their training set), they individually showed poor robustness for formulations outside the training set. However, a predictive algorithm based on the six models, trained only on binary samples, accurately predicts whether the correct amount of acetaminophen is present in ternary mixtures, genuine acetaminophen formulations, adulterated acetaminophen formulations, and falsified formulations containing substitute APIs. This data analytics approach may extend the utility of NIR spectrometers for analysis of pharmaceuticals in low-resource settings.
A new method for rapidly screening drinking water for the presence of per- and polyfluoroalkyl substances (PFAS) has been developed. This method involves gravity filtering drinking water through an activated carbon felt and subsequently analyzing the surface of the felt with particle induced gamma-ray emission (PIGE) spectroscopy. Using this technique, the total fluorine measurements by PIGE produced linear calibration curves adequate to measure below 50 ppt total fluorine from PFAS in drinking water for as little as 2 L of sample. Inorganic fluoride and PFAS were successfully differentiated by acidifying the sample prior to filtration. Acidification did not affect the anionic PFAS binding to the activated carbon filter, while the inorganic fluoride did not bind to the filter below pH 2. This method is quantitative when measuring individual PFAS; however, as a total fluorine measurement, PIGE cannot differentiate between individual PFAS in a mixed solution. Since most environmental or drinking water samples will likely contain a mixture of PFAS, this method could be used as a preliminary screening tool to identify samples with elevated total extractable organo-fluorine from anionic PFAS that can be analyzed by compound-specific methods subsequently to quantify individual analytes.
Background The opioid epidemic continues to be associated with high numbers of fatalities in the USA and other countries, driven mainly by the inclusion of potent synthetic opioids in street drugs. Drug checking by means of various technologies is being increasingly implemented as a harm reduction strategy to inform users about constituent drugs in their street samples. We assessed how valued drug checking services (DCS) would be for opioid street drug users given the ubiquity of fentanyl and related analogs in the drug supply, the information they would most value from drug checking, and compared expected versus actual constituent drugs in collected samples. Methods A convenience sample of opioid street drug users (N = 118) was recruited from two syringe service exchange programs in Chicago between 2021 and 2022. We administered brief surveys asking about overdose history, whether fentanyl was their preferred opioid, and interest in DCS. We also collected drug samples and asked participants what drug(s) they expected were in the sample. Provided samples were analyzed using LC–MS technology and the results compared to their expected drugs. Results Participants reported an average of 4.4 lifetime overdoses (SD = 4.8, range = 0–20) and 1.1 (SD = 1.8, range = 0–10) past-year overdoses. A majority (92.1%) believed they had recently used drugs containing fentanyl whether intentionally or unintentionally. Opinions about the desirability of fentanyl were mixed with 56.1% indicating they did not and 38.0% indicating they did prefer fentanyl over other opioids, mainly heroin. Attitudes toward DCS indicated a general but not uniform receptiveness with a majority indicating interest in DCS though sizeable minorities believed DCS was “too much trouble” (25.2%) or there was “no point” in testing (35.4%). Participants were especially inaccurate identifying common cutting agents and potentiating drugs such as diphenhydramine in their samples (sensitivity = .17). Conclusions Results affirmed street drug users remain interested in using DCS to monitor their drugs and such services should be more widely available. Advanced checking technologies that provide information on the relative quantities and the different drugs present in a given sample available at point-of-care, would be most valuable but remain challenging to implement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.