Background and objectiveThe extent to which deep brain stimulation (DBS) can improve quality of life may be perceived as a permanent trade-off between neurological improvements and complications of therapy, comorbidities, and disease progression.Patients and methodsWe retrospectively investigated 123 consecutive and non-preselected patients. Indications for DBS surgery were Parkinson's disease (82), dystonia (18), tremor of different etiology (21), Huntington's disease (1) and Gilles de la Tourette syndrome (1). AEs were defined as any untoward clinical occurrence, sign or patient complaint or unintended disease if related or unrelated to the surgical procedures, implanted devices or ongoing DBS therapy.ResultsOver a mean/median follow-up period of 4.7 years (578 patient-years) 433 AEs were recorded in 106 of 123 patients (86.2%). There was no mortality or persistent morbidity from the surgical procedure. All serious adverse events (SAEs) that occurred within 4 weeks of surgery were reversible. Neurological AEs (193 in 85 patients) and psychiatric AEs (78 in 48 patients) were documented most frequently. AEs in 4 patients (suicide under GPI stimulation, weight gain >20 kg, impairment of gait and speech, cognitive decline >2 years following surgery) were severe or worse, at least possibly related to DBS and non reversible. In PD 23.1% of the STN-stimulated patients experienced non-reversible (or unknown reversibility) AEs that were at least possibly related to DBS in the form of impaired speech or gait, depression, weight gain, cognitive disturbances or urinary incontinence (severity was mild or moderate in 15 of 18 patients). Age and Hoehn&Yahr stage of STN-simulated PD patients, but not preoperative motor impairment or response to levodopa, showed a weak correlation (r = 0.24 and 0.22, respectively) with the number of AEs.ConclusionsDBS-related AEs that were severe or worse and non-reversible were only observed in PD (4 of 82 patients; 4.9%), but not in other diseases. PD patients exhibited a significant risk for non-severe AEs most of which also represented preexisting and progressive axial and non-motor symptoms of PD. Mild gait and/or speech disturbances were rather frequent complaints under VIM stimulation. GPI stimulation for dystonia could be applied with negligible DBS-related side effects.
Background and objectiveTo determine rates of adverse events (AEs) related to deep brain stimulation (DBS) surgery or implanted devices from a large series from a single institution. Sound comparisons with the literature require the definition of unambiguous categories, since there is no consensus on the reporting of such AEs.Patients and methods123 consecutive patients (median age 63 yrs; female 45.5%) treated with DBS in the subthalamic nucleus (78 patients), ventrolateral thalamus (24), internal pallidum (20), and centre médian-parafascicular nucleus (1) were analyzed retrospectively. Both mean and median follow-up time was 4.7 years (578 patient-years). AEs were assessed according to three unambiguous categories: (i) hemorrhages including other intracranial complications because these might lead to neurological deficits or death, (ii) infections and similar AEs necessitating the explantation of hardware components as this results in the interruption of DBS therapy, and (iii) lead revisions for various reasons since this involves an additional intracranial procedure. For a systematic review of the literature AE rates were calculated based on primary data presented in 103 publications. Heterogeneity between studies was assessed with the I2 statistic and analyzed further by a random effects meta-regression. Publication bias was analyzed with funnel plots.ResultsSurgery- or hardware-related AEs (23) affected 18 of 123 patients (14.6%) and resolved without permanent sequelae in all instances. In 2 patients (1.6%), small hemorrhages in the striatum were associated with transient neurological deficits. In 4 patients (3.3%; 0.7% per patient-year) impulse generators were removed due to infection. In 2 patients electrodes were revised (1.6%; 0.3% per patient-year). There was no lead migration or surgical revision because of lead misplacement. Age was not statistically significant different (p>0.05) between patients affected by AEs or not. AE rates did not decline over time and similar incidences were found among all patients (423) implanted with DBS systems at our institution until December 2016. A systematic literature review revealed that exact AE rates could not be determined from many studies, which could not be attributed to study designs. Average rates for intracranial complications were 3.8% among studies (per-study analysis) and 3.4% for pooled analysis of patients from different studies (per-patient analysis). Annual hardware removal rates were 3.6 and 2.4% for per-study and per-patient analysis, respectively, and lead revision rates were 4.1 and 2.6%, respectively. There was significant heterogeneity between studies (I2 ranged between 77% and 91% for the three categories; p< 0.0001). For hardware removal heterogeneity (I2 = 87.4%) was reduced by taking study size (p< 0.0001) and publication year (p< 0.01) into account, although a significant degree of heterogeneity remained (I2 = 80.0%; p< 0.0001). Based on comparisons with health care-related databases there appears to be publication bias with lower rates fo...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.