on behalf of the J-RHYTHM Registry Investigators Background: Target anticoagulation levels for warfarin in Japanese patients with non-valvular atrial fibrillation (NVAF) are unclear.
Background—
The existence of an atypical fast-slow (F/S) atrioventricular nodal reentrant tachycardia (AVNRT) including a superior (sup) pathway with slow conductive properties and an atrial exit near the His bundle has not been confirmed.
Methods and Results—
We studied 6 women and 2 men (age, 74±7 years) with sup-F/S-AVNRT who underwent successful radiofrequency ablation near the His bundle. Programmed ventricular stimulation induced retrograde conduction over a superior SP with an earliest atrial activation near the His bundle, a mean shortest spike-atrial interval of 378±119 milliseconds, and decremental properties in all patients. sup-F/S-AVNRT was characterized by a long-RP interval; a retrograde atrial activation sequence during tachycardia identical to that over a sup-SP during ventricular pacing; ventriculoatrial dissociation during ventricular overdrive pacing of the tachycardia in 5 patients or atrioventricular block occurring during tachycardia in 3 patients, excluding atrioventricular reentrant tachycardia; termination of the tachycardia by ATP; and a V-A-V activation sequence immediately after ventricular induction or entrainment of the tachycardia, including dual atrial responses in 2 patients. Elimination or modification of retrograde conduction over the sup-SP by ablation near the right perinodal region or from the noncoronary cusp of Valsalva eliminated and confirmed the diagnosis of AVNRT in 4 patients each.
Conclusions—
sup-F/S-AVNRT is a distinct supraventricular tachycardia, incorporating an SP located above the Koch triangle as the retrograde limb, that can be eliminated by radiofrequency ablation.
In April 1988 a large outbreak of group C rotavirus infection associated with acute gastroenteritis occurred among schoolchildren and their teachers simultaneously at seven elementary schools in Fukui city, Japan. Of 3,102, 675 (21.8%) became ill. Clinical symptoms were mild, predominantly abdominal pain and vomiting, with diarrhea reported in only 27.6%. The outbreak subsided within 2 d. No pathogenic bacteria were found in fecal specimens; the virus particles detected by electron microscopy were morphologically indistinguishable from conventional infantile rotavirus. Immune electron microscopy showed that these virions formed large aggregates with convalescent serum and with the reference serum specific to group C rotavirus. Polyacrylamide gel electrophoresis showed similar RNA patterns for virus from this outbreak and typical group C rotavirus.
Background
The ablation index (AI) is reported to be useful for a durable pulmonary vein isolation (PVI). However, there have been no studies investigating the relationship between the power, contact force (CF), AI, and steam pops.
Methods
Using an in vitro model, ablation energy was delivered until a steam pop occurred and the time to the steam pop and AI when the steam pop occurred were measured. The experiment was performed with a combination of various powers (20, 30, 40, and 50 W) and contact forces (CFs) (10, 30, and 50 g) 20 times for each setting. The analysis consisted of two protocols. The first protocol was a comparison between the ablation power and several parameters under the same CF (10, 30, and 50 g). The second protocol was a comparison between the CF and several parameters under the same power (20, 30, 40, and 50 W). The correlation between the lesion formation and ablation parameters was evaluated.
Results
The AI value when steam pops occurred varied depending on the ablation settings. All AI median values were <500 under an ablation power of 50 W. On other hand, the median ablation time up to the steam pop was more than 46 seconds, but all median values of the AI were more than 550 under an ablation with 20 W.
Conclusions
The AI cannot predict steam pops. A low power and long duration ablation could obtain a high AI value. However, high‐power ablation could not obtain a high AI value because of an early occurrence of steam pops.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.