Bone remodeling is an expected sequela with total hip arthroplasty (THA). Although there are several methods of estimating bone response in THA patients from radiographs, there are no accurate and generally accepted methods for quantitative determinations in vivo. In this study, we describe an application of dual x-ray absorptiometry (DXA) for measuring bone mineral content and bone mineral density in the proximal femur following THA. DXA is a noninvasive technique with minimal radiation exposure (< 5 mrem). Various aspects of measurement error (accuracy and reliability) of this application of DXA were determined in a series of studies reported here. Accuracy error (how similar are the measured and actual values) was < 1% determined in bone phantoms of four densities. Precision error (how reproducible are the measurements) was also < 1% at all four densities in the phantoms and was only slightly elevated (0.9-1.5%) in repeated measurements of implanted cadaver femora. Precision error in vivo, determined both from multiple replicates on five patients and from duplicate scans on 30 patients, was further elevated but remained < 5%. Contributions to precision error, rotation of the leg, and interoperator variability were assessed; none was found to elevate precision error appreciably. We suggest that DXA is a feasible method for quantifying bone response following THA, and will allow discrimination of small changes (> 5%) not previously measurable.
Bone mineral content (BMC) and bone mineral density (BMD) of the proximal tibia were determined by dual photon absorptiometry on 44 women, aged 23-87 years. The area of the tibia measured was a 2.01 cm region immediately distal to the medial and lateral tuberosities. Values of BMC ranged between 5.09 and 14.57 g and BMD between 0.380 and 1.180 g/cm2. Both tibial BMC and BMD declined with age and tibial BMD was significantly correlated with lumbar spine (r = 0.70), femoral neck (r = 0.73), and femoral trochanter (r = 0.74). However, the large standard errors of estimate (SEE) (0.08-0.14 g/cm2) do not allow for reliable prediction in an individual of other skeletal sites by the tibia. Repeated measurements demonstrated that dual photon absorptiometry of the proximal tibia is a reliable measurement and may be a useful tool in the monitoring of therapeutic or intervention modalities in those individuals with skeletal diseases in whom measurement of the lumbar spine or proximal femur may not be possible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.