USPIO, a macromolecular particulate MR imaging contrast agent, can be applied successfully to characterize tumor microvessels in animals. USPIO-derived K(PS) correlated strongly with histopathologic tumor grade, MVD, and K(PS) values derived by using albumin-(Gd-DTPA)(30) in the same tumors.
Appropriate follow-up actions and decisions are needed when evaluating and interpreting clear positive results obtained in the in vitro assays used in the initial genotoxicity screening battery (i.e., the battery of tests generally required by regulatory authorities) to assist in overall risk-based decision making concerning the potential effects of human exposure to the agent under test. Over the past few years, the International Life Sciences Institute (ILSI) Health and Environmental Sciences Institute (HESI) Project Committee on the Relevance and Follow-up of Positive Results in In Vitro Genetic Toxicity (IVGT) Testing developed a decision process flow chart to be applied in case of clear positive results in vitro. It provides for a variety of different possibilities and allows flexibility in choosing follow-up action(s), depending on the results obtained in the initial battery of assays and available information. The intent of the Review Subgroup was not to provide a prescriptive testing strategy, but rather to reinforce the concept of weighing the totality of the evidence. The Review Subgroup of the IVGT committee highlighted the importance of properly analyzing the existing data, and considering potential confounding factors (e.g., possible interactions with the test systems, presence of impurities, irrelevant metabolism), and chemical modes of action when analyzing and interpreting positive results in the in vitro genotoxicity assays and determining appropriate follow-up testing. The Review Subgroup also examined the characteristics, strengths, and limitations of each of the existing in vitro and in vivo genotoxicity assays to determine their usefulness in any follow-up testing.
BLZ-100 is a single intravenous use, fluorescent imaging agent that labels tumor tissue to enable more complete and precise surgical resection. It is composed of a chlorotoxin peptide covalently bound to the near-infrared fluorophore indocyanine green. BLZ-100 is in clinical development for intraoperative visualization of human tumors. The nonclinical safety and pharmacokinetic (PK) profile of BLZ-100 was evaluated in mice, rats, canines, and non-human primates (NHP). Single bolus intravenous administration of BLZ-100 was well tolerated and no adverse changes were observed in cardiovascular safety pharmacology, PK, and toxicology studies in rats and NHP. The single-dose no-observed-adverse-effect-levels (NOAELs) were 7 mg (28 mg/kg) in rats and 60 mg (20 mg/kg) in NHP, corresponding to peak concentration values of 89,400 ng/mL and 436,000 ng/mL and area-under-the-curve exposure values of 130,000 hr*ng/mL and 1,240,000 hr*ng/mL, respectively. Based on a human imaging dose of 3 mg, dose safety margins are > 100 for rat and monkey. BLZ-100 produced hypersensitivity reactions in canine imaging studies (lethargy, pruritus, swollen muzzle, etc.). The severity of the reactions was not dose-related. In a follow-up study in dogs, plasma histamine concentrations were increased 5 to 60 minutes after BLZ-100 injection; this coincided with signs of hypersensitivity, supporting the conclusion that the reactions were histamine-based. Hypersensitivity reactions were not observed in other species or in BLZ-100 human clinical studies conducted to date. The combined imaging, safety pharmacology, PK, and toxicology studies contributed to an extensive initial nonclinical profile for BLZ-100, supporting first-in-human clinical trials.
MR images can be acquired with high spectral and spatial resolution to precisely measure lineshapes of the water and fat resonances in each image voxel. Previous work suggests that the high-resolution spectral information can be used to improve image contrast, SNR, sensitivity to contrast agents and to physiologic and biochemical processes that affect local magnetic susceptibility gradients. The potential advantages of high-resolution spectroscopic imaging (SI) suggest that it might be useful for early detection and characterization of tumors. The present experiments evaluate the use of high-resolution SI to discriminate between metastatic and nonmetastatic rodent Dunning prostate tumors. SI datasets were obtained at 4.7 Tesla with an in-plane resolution of 350 -500 in a single 1.0-mm slice, and 6 -8 Hz spectral resolution, before and after i.v. injection of an iron oxide contrast agent. Images of water signal peak height in nonmetastatic tumors were smoother in the tumor interior than images of metastatic tumors (P < .004 by t-test) before contrast media injection. This difference was stronger in contrast-enhanced images (P < .0004). In addition, the boundary between the tumor and muscle was more clearly demarcated in nonmetastatic than metastatic tumors. Combinations of image texture, tumor edge morphology, and changes in T * 2 following contrast media injection improved discrimination between metastatic and nonmetastatic tumors. The data presented here do not demonstrate that effective discrimination between metastatic and nonmetastatic tumors depends on the use of high-resolution SI. However, the results suggest that SI and/or other MR methods that provide similar contrast might be used clinically for early and accurate detection of metastatic disease. Magn Reson Med 45:1046 -1055, 2001.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.