This paper reports the first known investigation of power dissipation and electrical breakdown in aerosol-jet-printed (AJP) graphene interconnects. The electrical performance of aerosol-jet printed (AJP) graphene was characterized using the Transmission Line Method (TLM). The electrical resistance decreased with increasing printing pass number (n); the lowest sheet resistance measured was 1.5 kΩ/sq. for n = 50. The role of thermal resistance (RTH) in power dissipation was studied using a combination of electrical breakdown thermometry and infrared (IR) imaging. A simple lumped thermal model () and COMSOL Multiphysics was used to extract the total RTH, including interfaces. The RTH of AJP graphene on Kapton is ~27 times greater than that of AJP graphene on Al2O3 with a corresponding breakdown current density 10 times less on Kapton versus Al2O3.
Soft structural textiles, or softgoods, are used within the space industry for inflatable habitats, parachutes and decelerator systems. Evaluating the safety and structural integrity of these systems occurs through structural health monitoring systems (SHM), which integrate non-invasive/non-destructive testing methods to detect, diagnose, and locate damage. Strain/load monitoring of these systems is limited while utilizing traditional strain gauges as these gauges are typically stiff, operate at low temperatures, and fail when subjected to high strain that is a result of high loading classifying them as unsuitable for SHM of soft structural textiles. For this work, a capacitance based strain gauge (CSG) was fabricated via aerosol jet printing (AJP) using silver nanoparticle ink on a flexible polymer substrate. Printed strain gauges were then compared to a commercially available high elongation resistance-based strain gauge (HE-RSG) for their ability to monitor strained Kevlar straps having a 26.7 kN (6 klbf) load. Dynamic, static and cyclic loads were used to characterize both types of strain monitoring devices. Printed CSGs demonstrated superior performance for high elongation strain measurements when compared to commonly used HE-RSGs, and were observed to operate with a gauge factor of 5.2 when the electrode arrangement was perpendicular to the direction of strain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.