In hernia surgery, meshes with small pores tend to be filled by fibrous tissue, which reduces their stretchability and causes patient complaints. Because of the inelasticity of current meshes, mechanical strain might cause pores to collapse even in large-pore mesh constructions. In this study, a mesh with elastic thermoplastic polyurethane (TPU) filaments was constructed to prevent pore size changes even under mechanical strain, and its biocompatibility in comparison with polyvinylidene fluoride (PVDF) was evaluated. A mesh was constructed using PVDF with elastic TPU filaments and mechanically tested. After midline laparotomy in 20 rabbits, we placed a 15 cm × 3 cm mesh as inlay in the defect. Animals were randomized to either the TPU or PVDF group. After 7 or 21 days, mesh expansion was measured under pneumoperitoneum, and abdominal walls were explanted for immunohistochemical investigations. In vitro, TPU meshes showed a slight reduction in effective porosity from 46% at tension-free conditions to 26% under longitudinal and to 34% under transverse strain. The nonelastic PVDF meshes showed a marked reduction in effective porosity from 70% to 7% and 52%, respectively. The TPU mesh had a breaking elongation of 101% and a tensile strength of 35 N/cm. In vivo, both meshes achieved healing of the incision without hernial defect. The TPU mesh maintained its elasticity under pneumoperitoneum. The amount of CD68-positive, Ki67-positive, and apoptotic cells was significantly lower in the TPU group after 7 and 21 days. The newly developed TPU mesh shows elasticity, structural stability, and preserved effective porosity under mechanical strain. Immunohistochemistry indicates superior biocompatibility of TPU mesh compared with PVDF after 7 and 21 days.
The biocompatibility of a textile implant is determined by various parameters, such as material composition and surface chemistry. However, little is known about the influence of geometry of sutures on biocompatibility. To elucidate this factor we focused on geometry-modification resulting in ultrafine polyethylene terephthalate (UFPET) suture and a snowflake like shaped polyvenylidenfluorid (PVDF) suture. Forty-eight rats were divided into two observation periods. In each rat 3 out of 4 sutures (profiled UFPET, snowflake-like profiled PVDF, reference Prolene and Mersilene suture) were randomly placed into the subcutaneous tissue. Rats were euthanized after 7 and 21 days and samples were explanted. Foreign body granuloma was measured and expression of CD68, TUNEL, Ki-67 and Collagen I/III ratio were determined.The profiled (snowflake) suture showed a significantly smaller FBG in comparison to standard sutures (p < 0.001). Both modified sutures showed a significant lower tissue remodeling by Ki-67 and TUNEL expression (p < 0.03). Furthermore, profiled sutures caused a lower inflammatory reaction expressed in a significant lower amount of CD68 positive macrophages after 21 days (p < 0.001). Modifications of suture geometry alter the foreign body granuloma and the inflammatory reaction. Therefore, profiled sutures might be a promising approach to improve biocompatibility of textile mesh prosthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.