Intravenous injection of lipopolysaccharide and D-galactosamine, at doses of 0.2 micrograms/kg and 800 mg/kg, respectively, elicited massive hepatic necrosis within 24 hr in C3H/HeN mice. The plasma L-alanine aminotransferase (ALT, E.C. 2.6.1.2) or L-aspartate aminotransferase (AST, E.C. 2.6.1.1) activities at this point reached more than 2,000 IU/L. However, overt hepatic injury as evaluated by the plasma aminotransferase activities did not develop in mice in which only lipopolysaccharide or only D-galactosamine was injected. No tumor necrosis factor-like activities could be detected in the plasma of galactosamine- and lipopolysaccharide-injected mice as determined by the assay of cytotoxicity to highly tumor necrosis factor-sensitive L-P3 cells through the experimental period of 24 hr. However, passive immunization against mouse tumor necrosis factor-alpha with polyvalent rabbit anti-mouse tumor necrosis factor-alpha antiserum, which was able to neutralize the cytotoxic effects of recombinant mouse tumor necrosis factor-alpha on L-P3 cells, could protect the mice from the development of hepatic injury in a dose-dependent manner. Simultaneous injection of recombinant human tumor necrosis factor-alpha, instead of lipopolysaccharide, with 800 mg/kg of D-galactosamine in lipopolysaccharide-resistant C3H/HeJ mice sensitized the animals more than one thousand-fold to the development of hepatic injury. The livers appeared to be morphologically similar to those of galactosamine- and lipopolysaccharide-injected C3H/HeN mice.
Helicon waves generated by radio-frequency (rf) waves are experimentally demonstrated to have the characteristics of Landau damping, as predicted theoretically, and fully ionized plasmas are realized by this efficient coupling of rf powers to plasmas. Excited waves are identified as a helicon wave by measuring wavelengths in the plasma along the magnetic field and comparing with the dispersion relation. Good agreement is found between experimental and theoretical results.
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based chemical sensor, in which a measurement site on the sensing surface is defined by illumination. This light addressability can be applied to visualize the spatial distribution of pH or the concentration of a specific chemical species, with potential applications in the fields of chemistry, materials science, biology, and medicine. In this review, the features of this chemical imaging sensor technology are compared with those of other technologies. Instrumentation, principles of operation, and various measurement modes of chemical imaging sensor systems are described. The review discusses and summarizes state-of-the-art technologies, especially with regard to the spatial resolution and measurement speed; for example, a high spatial resolution in a submicron range and a readout speed in the range of several tens of thousands of pixels per second have been achieved with the LAPS. The possibility of combining this technology with microfluidic devices and other potential future developments are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.