Surfaces of metallic films and metallic nanoparticles can strongly confine electromagnetic field through its coupling to propagating or localized surface plasmons. This interaction is associated with large enhancement of the field intensity and local optical density of states which provides means to increase excitation rate, raise quantum yield, and control far field angular distribution of fluorescence light emitted by organic dyes and quantum dots. Such emitters are commonly used as labels in assays for detection of chemical and biological species. Their interaction with surface plasmons allows amplifying fluorescence signal (brightness) that accompanies molecular binding events by several orders of magnitude. In conjunction with interfacial architectures for the specific capture of target analyte on a metallic surface, plasmon-enhanced fluorescence (PEF) that is also referred to as metal-enhanced fluorescence (MEF) represents an attractive method for shortening detection times and increasing sensitivity of various fluorescence-based analytical technologies. This review provides an introduction to fundamentals of PEF, illustrates current developments in design of metallic nanostructures for efficient fluorescence signal amplification that utilizes propagating and localized surface plasmons, and summarizes current implementations to biosensors for detection of trace amounts of biomarkers, toxins, and pathogens that are relevant to medical diagnostics and food control.
We develop detachable "Cavitas sensors" to apply to the human oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor incorporating Pt and Ag/AgCl electrodes on a mouthguard support with an enzyme membrane is developed and tested. Electrodes are formed on the polyethylene terephthalate glycol (PETG) surface of the mouthguard. The Pt working electrode is coated with a glucose oxidase (GOD) membrane. The biosensor seamlessly is integrated with a glucose sensor and a wireless measurement system. When investigating in-vitro performance, the biosensor exhibits a robust relationship between output current and glucose concentration. In artificial saliva composed of salts and proteins, the glucose sensor is capable of highly sensitive detection over a range of 5-1000µmol/L of glucose, which encompasses the range of glucose concentrations found in human saliva. We demonstrate the ability of the sensor and wireless communication module to monitor saliva glucose in a phantom jaw imitating the structure of the human oral cavity. Stable and long-term real-time monitoring (exceeding 5h) with the telemetry system is achieved. The mouthguard biosensor will be useful as a novel method for real-time non-invasive saliva glucose monitoring for better management of dental patients.
In this study, a cellulose acetate (CA) membrane is formed as an interference rejection membrane on a glucose sensor to measure glucose in saliva. Glucose in saliva is successfully measured in vivo without any pretreatment of human saliva. A mouthguard (MG) glucose sensor is developed to monitor salivary glucose, which is reported to be correlated with the blood glucose level. Salivary components of ascorbic acid (AA) and uric acid (UA) hinder the accurate measurement of the glucose concentration of human saliva. CA-coated electrodes are prepared to investigate the interference rejection membrane. To measure hydrogen peroxide, which is a reaction product of glucose oxidase, effects of AA and UA are examined. Characteristics of the fabricated biosensor are examined on the basis of artificial saliva. The as-developed MG sensor can quantify the glucose concentration in the range of 1.75–10 000 μmol/L, which includes a salivary sugar concentration of 20–200 μmol/L. For the measurement of saliva samples collected from healthy subjects, the output corresponding to the concentration is confirmed; this suggests the possibility of glucose measurement. This MG glucose sensor can provide a useful method for the unrestricted and noninvasive monitoring of saliva glucose for the management of diabetes patients.
This paper describes unique plasmonic characteristics of two dimensional (2D) crystalline sheets composed of homogeneous Ag nanoparticles (AgNPs) fabricated by the Langmuir-Schaefer method at an air-water interface. The localized surface plasmon resonance (LSPR) band of the Ag nanosheet was tuned by changing the interparticle distance of AgNPs via the length of the organic capping molecules. Red shift of the LSPR band of the AgNPs sheet followed an exponential law against the interparticle distance in a similar manner to the previous reports of metal nanodisc pairs. However, the shift was much larger and less dependent on the interparticle separation gap. This phenomenon is reasonably interpreted as the long-range interaction of LSPR in the 2D sheet ('delocalized' LSPR) confirmed by simulation using the finite difference time domain (FDTD) method. The FDTD simulation also revealed additional enhancement of local electric fields on the 2D sheet compared to those on the single or paired particles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.