Anaerobic ammonium oxidation with nitrite to N2 (anammox) is a recently discovered microbial reaction with interesting potential for nitrogen removal from wastewater. We enriched an anammox culture from a rotating disk contactor (near Kölliken, Switzerland) that was used to treat ammonium-rich leachate with low organic carbon content. This enrichment led to a relative population size of 88% anammox bacteria. The microorganism carrying out the anammox reaction was identified by analysis of the 16S rDNA sequence and by fluorescence in situ hybridization (FISH) with 16S-rRNA-targeting probes. The percentage sequence identity between the 16S rDNA sequences of the Kölliken anammox organism and the archetype anammox strain Candidatus Brocadia anammoxidans was 90.9%, but between 98.5 and 98.9% with Candidatus Kuenenia stuttgartiensis, an organism identified in biofilms by molecular methods. The Kölliken culture catalyzed the anaerobic oxidation of ammonium with nitrite in a manner seemingly identical to that of Candidatus B. anammoxidans, but exhibited higher tolerance to phosphate (up to 20 mM) and to nitrite (up to 13 mM) and was active at lower cell densities. Anammox activity was observed only between pH 6.5 and 9, with an optimum at pH 8 and a temperature optimum at 37 degrees C. Hydroxylamine and hydrazine, which are intermediates of the anammox reaction of Candidatus B. anammoxidans, were utilized by the Kölliken organisms, and approximately 15% of the nitrite utilized during autotrophic growth was converted to nitrate. Electron microscopy showed a protein-rich region in the center of the cells surrounded by a doughnut-shaped region containing ribosomes and DNA. This doughnut-shape region was observed with FISH as having a higher fluorescence intensity. Similar to Candidatus B. anammoxidans, the Kölliken anammox organism typically formed homogenous clusters containing up to several hundred cells within an extracellular matrix.
The mechanism of significant nitrogen loss in an aerobic rotating biological contactor (RBC) treating ammonium-rich waste water could be identified with the aid of batch experiments, mathematical modeling and microbial analysis. It turned out that the aerobic ammonium and nitrite-oxidizing organisms (nitrosomonas and nitrobacter clusters) are dominant in the upper aerobic 100–200 μm of the biofilm. It is assumed that nitrite, appearing as an intermediate product close to the surface of the aerobic biofilm layer, diffuses into deeper anoxic layers of the biofilm. It is reduced anaerobically there in parallel with ammonium oxidized as described in the Anammox (anaerobic ammonium oxidation) process. This was confirmed in an anoxic batch test with suspended biofilm removed from the RBC. Unknown micro-organisms were detected, some of them similar to the Anammox organisms. A mathematical model which describes the kinetics of the aerobic ammonium-oxidizing, aerobic nitrite-oxidizing and anoxic ammonium-oxidizing micro-organisms was formulated and fitted into the AQUASIM biofilm compartment. The distribution of the populations within the biofilm as well as the ammonium, nitrite and nitrate degradation along the RBC in a steady state and during short-term experiments were modeled and compared with the experimental data.
High nitrogen losses were observed in a rotating biological contactor (RBC) treating ammonium-rich (up to 500 mg NH4(+)-N/L) but organic-carbon-poor leachate from a hazardous waste landfill in Kölliken, Switzerland. The composition and spatial structure of the microbial community in the biofilm on the RBC was analyzed with specific attention for the presence of aerobic ammonium and nitrite oxidizing bacteria and anaerobic ammonium oxidizers. Anaerobic ammonium oxidation (anammox) involves the oxidation of ammonium with nitrite to N2. First the diversity of the biofilm community was determined from sequencing cloned PCR-amplified 16S rDNA fragments. This revealed the presence of a number of very unusual 16S rDNA sequences, but very few sequences related to known ammonium or nitrite oxidizing bacteria. From analysis of biofilm samples by fluorescence in situ hybridization with known phylogenetic probes and by dot-blot hybridization of the same probes to total RNA purified from biofilm samples, the main groups of microorganisms constituting the biofilm were found to be ammonium-oxidizing bacteria from the Nitrosomonas europaea/eutropha group, anaerobic ammonium-oxidizing bacteria of the "Candidatus Kuenenia stuttgartiensis" type, filamentous bacteria from the phylum Bacteroidetes, and nitrite-oxidizing bacteria from the genus Nitrospira. Aerobic and anaerobic ammonium-oxidizing bacteria were present in similar amounts of around 20 to 30% of the biomass, whereas members of the CFB phylum were present at around 7%. Nitrite oxidizing bacteria were only present in relatively low amounts (less than 5% determined with fluorescence in situ hybridization). Data from 16S rRNA dot-blot and in situ hybridization were not in all cases congruent. FISH analysis of thin-sliced and fixed biofilm samples clearly showed that the aerobic nitrifiers were located at the top of the biofilm in an extremely high density and in alternating clusters. Anammox bacteria were exclusively present in the lower half of the biofilm, whereas CFB-type filamentous bacteria were present throughout the biofilm. The structure and composition of these biofilms correlated very nicely with the proposed physiological functional separations in ammonium conversion.
Partial nitrification of ammonium to nitrite under oxic conditions (nitritation) is a critical process for the effective use of alternative nitrogen removal technologies from wastewater. Here we investigated the conditions which promote establishment of a suitable microbial community for performing nitritation when starting from regular sewage sludge. Reactors were operated in duplicate under different conditions (pH, temperature, and dilution rate) and were fed with 50 mM ammonium either as synthetic medium or as sludge digester supernatant. In all cases, stable nitritation could be achieved within 10 to 20 days after inoculation. Quantitative in situ hybridization analysis with group-specific fluorescent rRNA-targeted oligonucleotides (FISH) in the different reactors showed that nitrite-oxidizing bacteria of the genus Nitrospira were only active directly after inoculation with sewage sludge (up to 4 days and detectable up to 10 days). As demonstrated by quantitative FISH and restriction fragment length polymorphism (RFLP) analyses of the amoA gene (encoding the active-site subunit of the ammonium monooxygenase), the community of ammonia-oxidizing bacteria changed within the first 15 to 20 days from a more diverse set of populations consisting of members of the Nitrosomonas communis and Nitrosomonas oligotropha sublineages and the Nitrosomonas europaea-Nitrosomonas eutropha subgroup in the inoculated sludge to a smaller subset in the reactors. Reactors operated at 30°C and pH 7.5 contained reproducibly homogeneous communities dominated by one amoA RFLP type from the N. europaea-N. eutropha group. Duplicate reactors at pH 7.0 developed into diverse communities and showed transient population changes even within the ammonia oxidizer community. Reactors at pH 7.5 and 25°C formed communities that were indistinguishable by the applied FISH probes but differing in amoA RFLP types. Communities in reactors fed with sludge digester supernatant exhibited a higher diversity and were constantly reinoculated with ammonium oxidizers from the supernatant. Therefore, such systems could be maintained at a higher dilution rate (0.75 day ؊1 compared to 0.2 day ؊1 for the synthetic wastewater reactors). Despite similar reactor performance with respect to chemical parameters, the underlying community structures were different, which may have an influence on stability during perturbations.Strong regulations exist nowadays for the removal of ammonium from wastewater discharge. Ammonium can lead to eutrophication of freshwater bodies and is toxic to aquatic life (11). The current method of removal of ammonium in wastewater treatment plants consists of a combination of aerobic nitrification catalyzed by autotrophic organisms and anaerobic denitrification catalyzed by heterotrophic organisms (40). In a first step, ammonium is oxidized to nitrate via nitrite, and in a second step, nitrate is reduced with organic carbon via nitrite to N 2 . This combination was long considered as the only way to remove ammonium from wastewater. However, m...
ObjectivesThe sensitivity of molecular and serological methods for COVID-19 testing in an epidemiological setting is not well described. The aim of the study was to determine the frequency of negative RT-PCR results at first clinical presentation as well as negative serological results after a follow-up of at least 3 weeks.MethodsAmong all patients seen for suspected COVID-19 in Liechtenstein (n=1921), we included initially RT-PCR positive index patients (n=85) as well as initially RT-PCR negative (n=66) for follow-up with SARS-CoV-2 antibody testing. Antibodies were detected with seven different commercially available immunoassays. Frequencies of negative RT-PCR and serology results in individuals with COVID-19 were determined and compared to those observed in a validation cohort of Swiss patients (n=211).ResultsAmong COVID-19 patients in Liechtenstein, false-negative RT-PCR at initial presentation was seen in 18% (12/66), whereas negative serology in COVID-19 patients was 4% (3/85). The validation cohort showed similar frequencies: 2/66 (3%) for negative serology, and 16/155 (10%) for false negative RT-PCR. COVID-19 patients with negative follow-up serology tended to have a longer disease duration (p=0.05) and more clinical symptoms than other patients with COVID-19 (p<0.05). The antibody titer from quantitative immunoassays was positively associated with the number of disease symptoms and disease duration (p<0.001).ConclusionsRT-PCR at initial presentation in patients with suspected COVID-19 can miss infected patients. Antibody titers of SARS-CoV-2 assays are linked to the number of disease symptoms and the duration of disease. One in 25 patients with RT-PCR-positive COVID-19 does not develop antibodies detectable with frequently employed and commercially available immunoassays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.