Stress response to robot-assisted colorectal surgery is largely unknown. Therefore, we conducted a prospective comparative nonrandomized study evaluating the perioperative dynamics of chemokines: IL-8/CXCL8, MCP-1/CCL2, MIP-1α/CCL3, MIP-1β/CCL4, RANTES/CCL5, and eotaxin-1/CCL11 in 61 colorectal cancer patients following open colorectal surgery (OCS) or robot-assisted surgery (RACS) in reference to clinical data. Postoperative IL-8 and MCP-1 increase was reduced in RACS with a magnitude of blood loss, length of surgery, and concomitant up-regulation of IL-6 and TNFα as its independent predictors. RANTES at 8 h dropped in RACS and RANTES, and MIP1α/β at 24 h were more elevated in RACS than OCS. IL-8 and MCP-1 at 72 h remained higher in patients subsequently developing surgical site infections, in whom a 2.6- and 2.5-fold increase was observed. IL-8 up-regulation at 24 h in patients undergoing open procedure was predictive of anastomotic leak (AL; 94% accuracy). Changes in MCP-1 and RANTES were predictive of delayed restoration of bowel function. Chemokines behave differently depending on procedure. A robot-assisted approach may be beneficial in terms of chemokine dynamics by favoring Th1 immunity and attenuated angiogenic potential and postoperative ileus. Monitoring chemokine dynamics may prove useful for predicting adverse clinical events. Attenuated chemokine up-regulation results from less severe blood loss and diminished inflammatory response.
Background. An endoleak is a typical complication of endovascular aneurysm repair (EVAR). It is characterized by persistent blood flow between a stent graft and the aneurysm sac. Usually, it can be visualized during primary EVAR, but in many cases, this remains impossible. Therefore, other methods of endoleak assessment are urgently needed. The measurement of aneurysm sac pressure (ASP) seems to be a promising direction of research in this area.Objectives. We aimed to evaluate the safety and efficacy of a new method for invasive pressure measurement inside the abdominal aortic aneurysm (AAA) during EVAR. We also assessed a correlation between pressure values and early angiographic occurrence of an endoleak after the procedure. Materials and methods.A total of 20 patients with AAA were included in this experimental prospective study. During EVAR, systolic, diastolic and mean pressure values were recorded both for ASP and aortic pressure (AP) before procedure, after stent graft opening and after final stent graft ballooning.Results. The measurements were successfully obtained in all participants without any complications. There were no significant differences between all ASP and AP before procedure. After the procedure, blood pressure significantly decreased in the aneurysm sac but not in the aorta. Systolic ASP was significantly lower than systolic AP both after stent graft opening (80.4 ±20.9 mm Hg compared to 110.7 ±21.6 mm Hg, p < 0.01) and after its balloon post-dilatation (65.6 ±26. 1 mm Hg compared to 107.4 ±22. 1 mm Hg, p < 0.001). Diastolic ASP decreased significantly in comparison to diastolic AP only after stent graft ballooning (48.0 ±14.6 mm Hg compared to 56.4 ±13.6 mm Hg, p < 0.05). Conclusions.Our study confirmed that the novel method for the measurement of ASP during EVAR, using a thin pressure wire, is feasible and safe.
IntroductionLaparoscopy has been introduced into the field of colorectal surgery with the aim of reducing morbidity. One of the major barriers to overcome is the steep learning curve. Robotic surgery offers substantial advantages over traditional laparoscopy, which make the whole procedure more user friendly.AimTo present our initial experiences with robotic assisted colorectal surgery.Material and methodsThirty-five patients with colorectal cancer underwent robotic assisted procedures between 2011 and 2013.ResultsIn total we performed 16 low anterior resections, 14 right colectomies, 3 abdominosacral resections and 2 left colectomies. There were 22 males and 13 females. The mean operative time was 315 ±65 min for a low anterior resection. The mean length of hospital stay was 6.4 ±1 days. There were 4 conversions to open procedures, 2 anastomotic leaks, and 1 colovaginal fistula. The mean lymph node yield was 12.7 ±4.3. The resection margin was negative in all but 1 patient.ConclusionsWe agree with the opinion that robotic surgery brings many advantages in pelvic dissections. In order to facilitate safe acquisition of robotic total mesorectal excision skills, surgeons should begin with female patients, and less advanced rectal cancer. In some instances robotic assistance can be helpful in right colectomies.
The first-ever case of a 54-year-old woman who overdosed on non-steroidal anti-inflammatory drugs in an attempt at suicide. Before that incident, she had not been treated for coexisting diseases such as rheumatoid arthritis or depression. At the time of admission to the General Surgery Department, the patient reported pains in the epigastric region with accompanying nausea and vomiting with mucous content as well as the inability to ingest food orally. Despite parenteral and enteral feeding, the patient exhibited a drop in body mass. The histopathologic examination of a sample taken from the stomach during gastroscopy showed some non-specific necrotic and inflammatory masses with granulation. Intraoperatively, a very small, infiltrated stomach with an initial section of duodenum was identified. A total stomach resection together with the reconstruction of digestive tract continuity was performed using the Roux-Y method. Histopathologic examination of the stomach revealed a deep, chronic and exacerbated inflammatory condition with an extensive ulceration over the entire length of the stomach, reaching up to the pylorus. Additionally, numerous lymphatic glands with inflammatory reaction changes were observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.