The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at p<0.05. Results : According to denture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD’s, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp p<0.01. The higher values of all periodontal parameter as BOP, PD, PI, CI and TM were in patients with RPD’s with claps comparing with RPD’s with attachment. Conclusion : RPD’s with clasp increased level of gingival inflammation in regions covered by the dentures and below the clasp arms in abutment teeth.
Objective:The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth.Materials and Methods:A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05).Results:The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05).Conclusions:With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.
Objective:The aim of the study was to analyze the distribution of color parameters, lightness (L*), chroma (C), hue (H), a* and b*, in the intercanine sector in maxilla.Material and Methods:Patients' tooth color measurements were performed using an intraoral spectrophotometer VITA Easyshade® (VITA Zahnfabrik H. Rauter GmbH and Co. KG, Bad Sackingen, Germany). The measurements were made in 255 subjects in the intercanine sector in maxilla.Results:The mean values for the group of 255 subjects were as follows: L*, a*, b*, C, and H as 81.6, 0.67, 21.6, 21.7, and 92.7, respectively. For F=206.27 and P < 0.001 between L*, a*, b*, C, H, and central incisor/lateral incisor/canines, there were statistically significant differences.Conclusion:With the statistical analysis, it was determined that there are significant color differences between the teeth of the intercanine sector, which differences are clinically significant also.
This retrospective clinical study aimed to assess patient’s satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period.Material and Methods:A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD.Result:The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%.Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient’s satisfaction with RPD with or without attachment.Conclusion:Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.
OBJECTIVE:This study aimed to evaluate maximum bite forces (mBF) in dominant (DS) and non-dominant sides (NDS) at certain time periods after the insertion of new complete dentures based on prior experience and gender.MATERIALS AND METHODS:A total of 88 patients, complete denture wearers (CDWs), were examined. The maximum bite force at the intercuspal position between the first molars in 3 seconds was registered and recorded with piezoelectric gnathodynamometer. The procedure was repeated 3 times in identical conditions, with relaxation intervals of 1 minute between repeats and the limiting factor was the subjective feeling of pain. Testing of parametric data was performed with One Way Repeated Measurement of ANOVA test.RESULTS:The average mBF values increased during the observational period, both on the DS and NDS, with significant difference in DS, which was greater. The analysis of one-factor variance showed that there were differences of average mBF values in DS and NDS during six consecutive measurements (mBF–DS = 11.3, p = 0.0001, and mBF-NDS = 2.26, p = 0.047). Significant changes in the masticatory force (mBF) on the DS and NDS is explained by different measurement times and with the prior experience with complete dentures, BF–DS = 11.76, p = 0.0000; mBF–NDS = 2.42, p = 0.0351; mBFe–DS = 40.48; P = 0.0000 mBFe–NDS = 39.93, p = 0.0000.CONCLUSION:mBF represents a significant discriminating variable of the level of functional adaptation of new complete denture wearers (nCDWs) about the initial measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.