Background and Objective The purpose of this study was to highlight the clinical performance of platelet-rich plasma (PRP) used as an adjunctive tool for regeneration in infrabony periodontal defects using different biomaterials or performing different surgical flap approaches. Comparative evaluation of main clinical outcomes as probing pocket depth reduction, clinical attachment gain, and recession reduction with and without the use of PRP has been analysed. Materials and Methods According to the focused question, an electronic and hand searching has been performed up to December 2016. From a batch of 73 articles, the selection strategy and Jadad quality assessment led us to include 15 studies for the meta-analysis. Results Despite the high heterogeneity found and the lack of complete data regarding the selected clinical outcomes, a comparative analysis has been possible by the categorization of used biomaterials and surgical flap approaches. This method led us to observe the best performance of grafts with the use of adjunctive PRP in CAL gain and PPD reduction. No difference has been outlined with a specific surgical flap. Conclusions Although PRP is considered a cheap and patient's derived growth factor, the not conclusive data reported would suggest that its use in addition to bone substitutes could be of some clinical benefit in the regenerative treatment of infrabony defects. Clinical Relevance This systematic review was intended to sort out the huge controversial debate in the field about the possible use of PRP in regenerative surgery in infrabony defect. The clinical relevance of using blood-borne growth factors to conventional procedures is effective as these could determine a better performance and outcomes despite the surgical approach adopted and limit the use of additional biomaterials for the blood clot stabilization.
Objective:The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth.Materials and Methods:A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05).Results:The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05).Conclusions:With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.
Objective:The aim of the study was to analyze the distribution of color parameters, lightness (L*), chroma (C), hue (H), a* and b*, in the intercanine sector in maxilla.Material and Methods:Patients' tooth color measurements were performed using an intraoral spectrophotometer VITA Easyshade® (VITA Zahnfabrik H. Rauter GmbH and Co. KG, Bad Sackingen, Germany). The measurements were made in 255 subjects in the intercanine sector in maxilla.Results:The mean values for the group of 255 subjects were as follows: L*, a*, b*, C, and H as 81.6, 0.67, 21.6, 21.7, and 92.7, respectively. For F=206.27 and P < 0.001 between L*, a*, b*, C, H, and central incisor/lateral incisor/canines, there were statistically significant differences.Conclusion:With the statistical analysis, it was determined that there are significant color differences between the teeth of the intercanine sector, which differences are clinically significant also.
This retrospective clinical study aimed to assess patient’s satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period.Material and Methods:A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD.Result:The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%.Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient’s satisfaction with RPD with or without attachment.Conclusion:Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.
OBJECTIVE:This study aimed to evaluate maximum bite forces (mBF) in dominant (DS) and non-dominant sides (NDS) at certain time periods after the insertion of new complete dentures based on prior experience and gender.MATERIALS AND METHODS:A total of 88 patients, complete denture wearers (CDWs), were examined. The maximum bite force at the intercuspal position between the first molars in 3 seconds was registered and recorded with piezoelectric gnathodynamometer. The procedure was repeated 3 times in identical conditions, with relaxation intervals of 1 minute between repeats and the limiting factor was the subjective feeling of pain. Testing of parametric data was performed with One Way Repeated Measurement of ANOVA test.RESULTS:The average mBF values increased during the observational period, both on the DS and NDS, with significant difference in DS, which was greater. The analysis of one-factor variance showed that there were differences of average mBF values in DS and NDS during six consecutive measurements (mBF–DS = 11.3, p = 0.0001, and mBF-NDS = 2.26, p = 0.047). Significant changes in the masticatory force (mBF) on the DS and NDS is explained by different measurement times and with the prior experience with complete dentures, BF–DS = 11.76, p = 0.0000; mBF–NDS = 2.42, p = 0.0351; mBFe–DS = 40.48; P = 0.0000 mBFe–NDS = 39.93, p = 0.0000.CONCLUSION:mBF represents a significant discriminating variable of the level of functional adaptation of new complete denture wearers (nCDWs) about the initial measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.