An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor. This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank. This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system. At first, the decay tank was designed and improved step by step, while considering the computational fluid dynamics analysis results. Consequently, we could satisfy the design requirements of the decay tank. In addition, the performance of a new type of siphon breaker that was installed in the final decay tank model was tested. We designed an 18-inch diameter siphon breaker at the top of the decay tank's third section, and we could observe the breaking of the siphon that prevented the occurrence of a severe accident in the research reactor. By locating the siphon breaker at the third section of the decay tank, we could also use the coolant of the front three sections for long-term cooling of the research reactor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.