Both PRISM anti-HBc assays revealed that approximately 1.8% of non-prescreened blood donors from Germany were reactive for anti-HBc. Although sensitivity was comparable between both assays, specificity was increased significantly with the PRISM HBcore. High anti-HBc sample cut-off values were indicative for reactivity in other HBV parameters and for concordant results in the nine different anti-HBc assays. Look-back investigations are necessary to estimate the infection risk both of anti-HBc-only positive and of anti-HBc/anti-HBs-positive blood transfusions.
Compared to HIV and hepatitis C virus, the residual infectious risk of hepatitis B virus (HBV) posed by blood products is about 10 times higher. In addition to HBsAg testing, screening for anti-HBc was recommended by the German Advisory Committee Blood in March 2005. Prevalence of anti-HBc in German blood donors was investigated at five test sites located in different geographic regions. In total, 12,000 blood donors were screened for anti-HBc by PRISM HBcore, and a statistically representative number of these were tested with Abbott Murex anti-HBc total, bioMérieux Hepanostika anti-HBc uniform, Bio-Rad Monolisa anti-HBc PLUS and Dade Behring Enzygnost anti-HBc. Anti-HBc repeat reactive samples were tested for anti-HBs, anti-HBe and HBV DNA by individual donation NAT. The mean prevalence of anti-HBc was 1.75% in donors that had not been tested for anti-HBc in the past. The percentage of anti-HBs in anti-HBc repeat reactive donors was 93.7%. Samples that were additionally reactive for anti-HBe were anti-HBc reactive in all tested assays. The sample to cut-off (S/Co) values for anti-HBc were lower (competitive assays) in samples that were also positive for anti-HBe, when compared to samples that were only anti-HBc reactive. Most commercially available anti-HBc assays provide sufficient sensitivity for routine screening purposes, and lacking specificity is no longer a serious issue for most of them. Assay differences were recognized for samples that were anti-HBc only reactive. The overall loss of 1.75% of positive testing donors can be significantly reduced to 0.45% by implementation of re-entry procedures for donors with an anti-HBs titre of over 100 IU/l and negative by sensitive ID-NAT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.