Background
Advances in imaging, biomaterials and precision radiotherapy provide new opportunities to salvage locally recurrent prostate cancer (PC). This study evaluates the efficacy and safety of re-irradiation using stereotactic body radiation therapy (SBRT). We hypothesized that patients with castrate-resistant PC (CRPC) would benefit less from local salvage.
Methods
A prospective clinical database was reviewed to extract 30 consecutive patients treated with prostate re-irradiation. Gallium prostate specific membrane antigen (PSMA) ligand positron emission tomography was performed following prostate-specific antigen failure in all patients and biopsy was obtained in 18 patients (60%). Re-irradiation was either focal (n = 13) or whole-gland (n = 17). Endo-rectal balloons were used in twenty-two patients and hydrogel spacers in eight patients. The median prescription dose was 5 fractions of 6.5 (range: 6–8) Gray (Gy).
Results
Median follow-up was 28 months. Failure occurred in 10 (out of 11) CRPC patients versus 6 (out of 19) castrate-sensitive patients (91% vs. 32%, p = 0.008) after a median of 13 and 23 months, respectively. Metastases occurred in 64% (n = 7) of CRPC patients versus 16% (n = 3) of castrate-sensitive patients (p = 0.007). Two patients experienced local in-field recurrence, thus local control was 93%. The 2 and 3-year recurrence-free survival were 84% and 79% for castrate-sensitive patients versus 18% and 9% for CRPC patients (p < 0.001), and 3-year metastasis-free survival was 90% versus 27% (p < 0.01) for castrate-sensitive and CRPC patients, respectively. Acute grade II and III genitourinary (GU) toxicity occurred in 27% and 3%, and late GU toxicity in 30% and 3%, respectively. No ≥ grade II acute gastrointestinal (GI) toxicity occurred, and only one patient (3%) developed late grade II toxicity.
Conclusions
Early delivery of salvage SBRT for local recurrence is associated with excellent 3-year disease control and acceptable toxicity in the castrate-sensitive phenotype. PSMA imaging for detection of local recurrence and the use of precision radiotherapy with rectal protective devices should be further investigated as a novel salvage strategy for radio-recurrent PC.
BackgroundThis is a dosimetric comparative study intended to establish appropriate low-to-intermediate dose-constraints for the rectal wall (Rwall) in the context of a randomized phase-II trial on urethra-sparing stereotactic body radiotherapy (SBRT) for prostate cancer. The effect of plan optimization on low-to-intermediate Rwall dose and the potential benefit of an endorectal balloon (ERB) are investigated.MethodsTen prostate cancer patients, simulated with and without an ERB, were planned to receive 36.25Gy (7.25Gyx5) to the planning treatment volume (PTV) and 32.5Gy to the urethral planning risk volume (uPRV). Reference plans with and without the ERB, optimized with respect to PTV and uPRV coverage objectives and the organs at risk dose constraints, were further optimized using a standardized stepwise approach to push down dose constraints to the Rwall in the low to intermediate range in five sequential steps to obtain paired plans with and without ERB (Vm1 to Vm5). Homogeneity index for the PTV and the uPRV, and the Dice similarity coefficient (DSC) for the PTV were analyzed. Dosimetric parameters for Rwall including the median dose and the dose received by 10 to 60% of the Rwall, bladder wall (Bwall) and femoral heads (FHeads) were compared. The monitor units (MU) per plan were recorded.ResultsVm4 reduced by half D30%, D40%, D50%, and Dmed for Rwall and decreased by a third D60% while HIPTV, HIuPRV and DSC remained stable with and without ERB compared to Vmref. HIPTV worsened at Vm5 both with and without ERB. No statistical differences were observed between paired plans on Rwall, Bwall except a higher D2% for Fheads with and without an ERB.ConclusionsFurther optimization to the Rwall in the context of urethra sparing prostate SBRT is feasible without compromising the dose homogeneity to the target. Independent of the use or not of an ERB, low-to-intermediate doses to the Rwall can be significantly reduced using a four-step sequential optimization approach.
Purpose. Spine stereotactic radiosurgery (SRS) delivers an accurate and efficient high radiation dose to vertebral metastases in 1–5 fractions. We aimed to compare volumetric modulated arc therapy (VMAT) to static beam intensity modulated radiotherapy (IMRT) for spine SRS. Methods and Materials. Ten spine lesions of previously treated SRS patients were planned retrospectively using both IMRT and VMAT with a prescribed dose of 16 Gy to 100% of the planning target volume (PTV). The plans were compared for conformity, homogeneity, treatment delivery time, and safety (spinal cord dose). Results. All evaluated parameters favored the VMAT plan over the IMRT plans. D
min in the IMRT was significantly lower than in the VMAT plan (7.65 Gy/10.88 Gy, p < 0.001), the Dice Similarity Coefficient (DSC) was found to be significantly better for the VMAT plans compared to the IMRT plans (0.77/0.58, resp., p value < 0.01), and an almost 50% reduction in the net treatment time was calculated for the VMAT compared to the IMRT plans (6.73 min/12.96 min, p < 0.001). Conclusions. In our report, VMAT provides better conformity, homogeneity, and safety profile. The shorter treatment time is a major advantage and not only provides convenience to the painful patient but also contributes to the precision of this high dose radiation therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.