Chimeric antigen receptor modified T cells targeting CD19 and CD20 have shown activity in Phase I, II trials of patients with hematological malignancies. We conducted a systematic review and meta-analysis of all published clinical trials studying the role of efficacy as well as safety of CD-19 and CD-20 chimeric antigen receptor-T therapy for B-cell hematologic malignancies. A total of 16 studies with 195 patients were identified. The pooled analysis showed an overall response rate of 61% (118/195) with complete response of 42% (81/195) and partial response of 19% (37/195). Major adverse events were cytokine release syndrome 33%, neurotoxicity 33% and B-cell aplasia 54%. Collectively, the results indicate encouraging response in relapsed/refractory B lymphoma and leukemia, especially in acute lymphoblastic leukemia (ALL) patients.
Background:Extracranial–intracranial bypass is a challenging procedure that requires special microsurgical skills and an operative microscope. The exoscope is a tool for neurosurgical visualization that provides view on a heads-up display similar to an endoscope, but positioned external to the operating field, like a microscope. The authors carried out a proof-of-concept study evaluating the feasibility and effectiveness of performing microvascular bypass using various new exoscopic tools.Methods:We evaluated microsurgical procedures using a three-dimensional (3D) endoscope, hands-free robotic automated positioning two-dimensional (2D) exoscope, and an ocular-free 3D exoscope, including surgical gauze knot tying, surgical glove cutting, placental vessel anastomoses, and rat vessel anastomoses. Image quality, effectiveness, and feasibility of each technique were compared among different visualization tools and to a standard operative microscope.Results:3D endoscopy produced relatively unsatisfactory resolution imaging. It was shown to be sufficient for knot tying and anastomosis of a placental artery, but was not suitable for anastomosis in rats. The 2D exoscope provided higher resolution imaging, but was not adequate for all maneuvers because of lack of depth perception. The 3D exoscope was shown to be functional to complete all maneuvers because of its depth perception and higher resolution.Conclusion:Depth perception and high resolution at highest magnification are required for microvascular bypass procedures. Execution of standard microanastomosis techniques was unsuccessful using 2D imaging modalities because of depth-perception-related constraints. Microvascular anastomosis is feasible under 3D exoscopic visualization; however, at highest magnification, the depth perception is inferior to that provided by a standard operative microscope, which impedes the procedure.
Coronavirus disease 2019 (COVID-19) pandemic is expanding at an enormous pace and has already affected over 15 million population. 1 Individuals with comorbidities are the worst affected with risk factors like old age, diabetes, chronic airway disease, immunosuppressed, and cancer. 2 Sickle cell disease
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.