Atrial fibrillatory cycle length is inversely associated with the number of sources participating in AF maintenance observed in the computer model. In addition, AFCL is an important predictor of baseline duration of the arrhythmia, type of AF, and ease of catheter ablation therapy to terminate AF.
This initial 50-patient multicenter study demonstrates a 80% short-term and 66% success rate at 20 months, with a low complication rate and a relatively short procedure time in patients with persistent AF using 3 anatomically specific multielectrode ablation catheters and low-energy duty-cycled radiofrequency energy.
METHODS. A prototype algorithm, developed from first principles of electrostatic field theory, derives charge density (CD) as a spatial representation of the true sources of the cardiac field. The algorithm processes multiple, simultaneous, noncontact voltage measurements within the cardiac chamber to inversely derive the global distribution of CD sources across the endocardial surface. RESULTS. Comparison of CD to an established computer-simulated model of atrial conduction demonstrated feasibility in terms of spatial, temporal, and morphologic metrics. Inverse reconstruction matched simulation with median spatial errors of 1.73 mm and 2.41 mm for CD and voltage, respectively. Median temporal error was less than 0.96 ms and morphologic correlation was greater than 0.90 for both CD and voltage. Activation patterns observed in human atrial flutter reproduced those established through contact maps, with a 4-fold improvement in resolution noted for CD over voltage. Global activation maps (charge density-based) are reported in atrial fibrillation with confirmed reduction of far-field interference. Arrhythmia cycle-length slowing and termination achieved through ablation of critical points demonstrated in the maps indicates both mechanistic and pathophysiological relevance. CONCLUSION. Global maps of cardiac activation based on CD enable classification of conduction patterns and localized nonpulmonary vein therapeutic targets in atrial fibrillation. The measurement capabilities of the approach have roles spanning deep phenotyping to therapeutic application. TRIAL REGISTRATION. ClinicalTrials.gov NCT01875614.
Abstract-Atrial fibrillation (AF) is the most common form of cardiac arrhythmia. Surgical/Radiofrequency (RF) ablation is a therapeutic procedure that consists of creating lines of conduction block to interrupt AF. The present study evaluated 13 different ablation patterns by means of a biophysical model of the human atria. In this model, ablation lines were abruptly applied transmurally during simulated sustained AF, and success rate, time to AF termination and average beat-to-beat interval were documented. The gold standard Cox's Maze III procedure was taken as reference. The effectiveness of twelve less invasive patterns was compared to it. In some of these incomplete lines (entailing a gap) were simulated. Finally, the computer simulations were compared to clinical data. The results show that the model reproduces observations made in vivo: (1) the Maze III is the most efficient ablation procedure; (2) less invasive patterns should include lines in both right and left atrium; (3) incomplete ablation lines between the pulmonary veins and the mitral valve annulus lead to uncommon flutter; (4) computer simulations of incomplete lines are consistent with clinical results of non-transumural RF ablation. Biophysical modeling may therefore be considered as a useful tool for understanding the mechanisms underlying AF therapies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.