Abstract-Atrial fibrillation (AF) is the most common form of cardiac arrhythmia. Surgical/Radiofrequency (RF) ablation is a therapeutic procedure that consists of creating lines of conduction block to interrupt AF. The present study evaluated 13 different ablation patterns by means of a biophysical model of the human atria. In this model, ablation lines were abruptly applied transmurally during simulated sustained AF, and success rate, time to AF termination and average beat-to-beat interval were documented. The gold standard Cox's Maze III procedure was taken as reference. The effectiveness of twelve less invasive patterns was compared to it. In some of these incomplete lines (entailing a gap) were simulated. Finally, the computer simulations were compared to clinical data. The results show that the model reproduces observations made in vivo: (1) the Maze III is the most efficient ablation procedure; (2) less invasive patterns should include lines in both right and left atrium; (3) incomplete ablation lines between the pulmonary veins and the mitral valve annulus lead to uncommon flutter; (4) computer simulations of incomplete lines are consistent with clinical results of non-transumural RF ablation. Biophysical modeling may therefore be considered as a useful tool for understanding the mechanisms underlying AF therapies.
AimsManaged ventricular pacing (MVP) and Search AV+ are representative dual-chamber pacing algorithms for minimizing ventricular pacing (VP). This randomized, crossover study aimed to examine the difference in ability to reduce percentage of VP (%VP) between these two algorithms.Methods and resultsSymptomatic bradyarrhythmia patients implanted with a pacemaker equipped with both algorithms (Adapta DR, Medtronic) were enrolled. The %VPs of the patients during two periods were compared: 1 month operation of either one of the two algorithms for each period. All patients were categorized into subgroups according to the atrioventricular block (AVB) status at baseline: no AVB (nAVB), first-degree AVB (1AVB), second-degree AVB (2AVB), episodic third-degree AVB (e3AVB), and persistent third-degree AVB (p3AVB). Data were available from 127 patients for the analysis. For all patient subgroups, except for p3AVB category, the median %VPs were lower during the MVP operation than those during the Search AV+ (nAVB: 0.2 vs. 0.8%, P < 0.0001; 1AVB: 2.3 vs. 27.4%, P = 0.001; 2AVB: 16.4% vs. 91.9%, P = 0.0052; e3AVB: 37.7% vs. 92.7%, P = 0.0003).ConclusionManaged ventricular pacing algorithm, when compared with Search AV+, offers further %VP reduction in patients implanted with a dual-chamber pacemaker, except for patients diagnosed with persistent loss of atrioventricular conduction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.