There appear to be differences in the natural history of UC in our African American patients when compared with Caucasian controls, while ethnicity was not shown to be a risk factor for colectomy.
CTE, GGE, MRI, and PES offer complementary information on disorders of the pouch and the combination of these tests increases diagnostic accuracy for complex cases.
Hip resurfacing is an attractive alternative to total hip replacement preserving bone and reducing dislocation risk. Recent metal-on-metal designs have caused failure due to metal wear debris. Ceramic implants may mitigate this risk. Deformation of the acetabular cup can affect the lubrication, producing high friction torques between the femoral head and the cup that would increase wear and/or lead to cup loosening due to femoral head clamping. Our objective was to quantify the deformation of a novel monobloc ceramic hip resurfacing cup component compared to a metal standard, in a fresh frozen cadaveric model using a press-fit technique representative of standard surgical conditions. For this study eight acetabula were prepared from four fresh frozen cadavers. One surgeon with extensive experience in hip resurfacing surgery (J.H.) prepared the acetabulum by sequential reaming. The implants were then impacted into the acetabulum. Four ceramic and four metal implants were used of equal and varying size. Deformation was measured peri-implantation, and at 30 min, using an optical high-precision deformation sensor (GOM GmbH, Braunschweig, Germany). The maximum inscribed circle and the measurement of radial segment techniques were used. Deformation was greater in the metal implants (mean: 34–22mm) immediately after implantation. At 30 min after implantation, the deformation increased to 36mm in the metal and 26mm in the ceramic cup. Greater diameter changes were observed in larger cups. Metal and ceramic implants did not return to the initial diameter. We conclude the ceramic resurfacing acetabular implants undergo similar deformation to existing metal-on-metal implants. The deformation observed was significantly less in the ceramic component at 30 min on one measure. Less deformation may result in better surface conditions and wear characteristics. Deformation change did not resolve after 30 min for both implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.