As additive manufacturing of polymeric materials is becoming more prevalent throughout industry and research communities, it is important to ensure that 3D printed parts are able to withstand mechanical and environmental stresses that occur when in use, including the sub-critical cyclic loads that could result in fatigue crack propagation and material failure. There has so far been only limited research on the fatigue behavior of 3D printed polymers to determine which printing or material parameters result in the most favorable fatigue behavior. To better understand the effects of the printing technique, printing materials, and printing parameters on the fatigue behavior of 3D printed materials, we present here an overview of the data currently available in the literature including fatigue testing protocols and a quantitative analysis of the available fatigue data per type of the AM technology. The results of our literature review clearly show that, due to the synergism between printing parameters and the properties of the printed material, it is challenging to determine the best combination of variables for fatigue resistance. There is therefore a need for more experimental and computational fatigue studies to understand how the above-mentioned material and printing parameters affect the fatigue behavior.
Background: Osseointegrated implants for transfemoral amputees facilitate direct load transfer between the prosthetic limb and femur; however, implant loosening is a common complication, and the associated implant-bone loads remain poorly understood. This case study aimed to use patient-specific computational modelling to evaluate bone-implant interface loading during standing and walking in a transfemoral amputee with an osseointegrated implant prior to prosthesis loosening and revision surgery.Methods: One male transfemoral amputee with an osseointegrated implant was recruited (age: 59-yrs, weight: 83kg) and computed tomography (CT) performed on the residual limb approximately 3 months prior to implant failure. Gait analyses were performed, and the CT images used to develop a finite element model of the patient's implant and surrounding bone. Simulations of static weight bearing, and over-ground walking were then performed.Findings: During standing, maximum and minimum principal strains in trabecular bone adjacent to the implant were 0.26% and -0.30%, respectively. Strains generated at the instant of contralateral toe-off and contralateral heel strike during walking were substantially higher and resulted in local trabecular bone yielding. Specifically, the maximum and minimum principal strains in the thin layer of trabecular bone surrounding the distal end of the implant were 1.15% and -0.98%, respectively.Interpretation: Localised yielding of trabecular bone at the interface between the femur and implant in transfemoral amputee osseointegrated prosthesis recipients may present a risk of implant loosening due to periprosthetic bone fracture during walking.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.