Venous thromboembolism (VTE) is a serious complication during and after hospitalization, yet is a preventable cause of in-hospital death.Without VTE prophylaxis, the overall VTE incidence in medical and general surgery hospitalized patients is in the range of 10% to 40%, while it ranges up to 40% to 60% in major orthopaedic surgery. With routine VTE prophylaxis, fatal pulmonary embolism is uncommon in orthopaedic patients and the rates of symptomatic VTE within three months are in the range of 1.3% to 10%.VTE prophylaxis methods are divided into mechanical and pharmacological. The former include mobilization, graduated compression stockings, intermittent pneumatic compression device and venous foot pumps; the latter include aspirin, unfractionated heparin, low molecular weight heparin (LMWH), adjusted dose vitamin K antagonists, synthetic pentasaccharid factor Xa inhibitor (fondaparinux) and newer oral anticoagulants. LMWH seems to be more efficient overall compared with the other available agents. We remain sceptical about the use of aspirin as a sole method of prophylaxis in total hip and knee replacement and hip fracture surgery, while controversy still exists regarding the use of VTE prophylaxis in knee arthroscopy, lower leg injuries and upper extremity surgery.Cite this article: EFORT Open Rev 2018;3:136-148. DOI: 10.1302/2058-5241.3.170018
The lifetime risk for diabetic patients to develop a diabetic foot ulcer (DFU) is 25%. In these patients, the risk of amputation is increased and the outcome deteriorates.More than 50% of non-traumatic lower-extremity amputations are related to DFU infections and 85% of all lower-extremity amputations in patients with diabetes are preceded by an ulcer; up to 70% of diabetic patients with a DFU-related amputation die within five years of their amputation.Optimal management of patients with DFUs must include clinical awareness, adequate blood glucose control, periodic foot inspection, custom therapeutic footwear, off-loading in high-risk patients, local wound care, diagnosis and control of osteomyelitis and ischaemia.Cite this article: EFORT Open Rev 2018;3:513-525. DOI: 10.1302/2058-5241.3.180010
Graft infection following aortic aneurysms repair is an uncommon but devastating complication; its incidence ranges from <1% to 6% (mean 4%), with an associated perioperative and overall mortality of 12% and 17.5-20%, respectively. The most common causative organisms are Staphylococcus aureus and Escherichia coli; causative bacteria typically arise from the skin or gastrointestinal tract. The pathogenetic mechanisms of aortic graft infections are mainly breaks in sterile technique during its implantation, superinfection during bacteremia from a variety of sources, severe intraperitoneal or retroperitoneal inflammation, inoculation of bacteria during postoperative percutaneous interventions to manage various types of endoleaks, and external injury of the vascular graft. Mechanical forces in direct relation to the device were implicated in fistula formation in 35% of cases of graft infection. Partial rupture and graft migration leading to gradual erosion of the bowel wall and aortoenteric fistulas have been reported in 30.8% of cases.Rarely, infection via continuous tissues may affect the spine, resulting in spondylitis. Even though graft explantation and surgical debridement is usually the preferred course of action, comorbidities and increased perioperative risk may preclude patients from surgery and endorse a conservative approach as the treatment of choice. In contrast, conservative treatment is the treatment of choice for spondylitis; surgery may be indicated in approximately 8.5% of patients with neural compression or excessive spinal infection. To enhance the literature, we searched the related literature for published studies on continuous spondylitis from infected endovascular grafts aiming to summarize the pathogenesis and diagnosis, and to discuss the treatment and outcome of the patients with these rare and complex infections.
To discuss all relevant considerations for harvesting, culture, differentiation and phenotypic characterization of ADSCs, to provide a comprehensive roadmap of this process, to identify the differences between ADSCs obtained from various adipose tissues of the rat, and to provide FT-IR spectroscopy marker bands that could be used as fingerprints to differentiate the types of adipose tissues.
Four-corner fusion is a reliable limited wrist fusion technique that provides pain relief, grip strength and satisfactory range of motion in patients with degenerative conditions of the wrist. Partial union is more common with Kirschner wire fixation and complications are more common with circular plate fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.