Objective
Preexisting severe cervical spinal cord compression is a significant risk factor in cervical hyperextension injury, and the neurological function may deteriorate after a slight force to the forehead. There are few biomechanical studies regarding the influence of pathological factors in hyperextension loading condition. The aim of this study is to analyze the effects of preexisting different types of cervical disc herniation and different degrees of compression on the spinal cord in cervical hyperextension.
Method
A 3D finite element (FE) model of cervical spinal cord was modeled. Local type with median herniation, local type with lateral herniation, diffuse type with median herniation, and diffuse type with lateral herniation were simulated in neutral and extention positions. The compressions which were equivalent to 10%, 20%, 30%, and 40% of the sagittal diameter of the spinal cord were modeled.
Results
The results of normal FE model were consistent with those of previous studies. The maximum von Mises stresses appeared in the pia mater for all 32 loading conditions. The maximum von Mises stresses in extension position were much higher than in neutral position. In most cases, the maximum von Mises stresses in diffuse type were higher than in local type.
Conclusion
Cervical spinal cord with preexisting disc herniation is more likely to be compressed in hyperextension situation than in neutral position. Diffuse type with median herniation may cause more severe compression with higher von Mises stresses concentrated at the anterior horn and the peripheral white matter, resulting in acute central cord syndrome from biomechanical point of view.
Knowledge of the dynamic behavior of the spinal cord under different testing conditions is critical for our understanding of biomechanical mechanisms of spinal cord injury. Although velocity and contact stress area are known to affect external mechanical stress or energy upon sudden traumatic injury, quantitative investigation of the two clinically relevant biomechanical variables is limited. Here, freshly excised rat spinal-cord–pia-arachnoid constructs were tested through indentation using indenters of different sizes (radii: 0.25, 0.50, and 1.00 mm) at various loading rates ranging from 0.04 to 0.20 mm/s. This analysis found that the ex vivo specimen displayed significant nonlinear viscoelasticity at <10% of specimen thickness depth magnitudes. At higher velocity and larger contact stress area, the cord withstood a higher peak load and exhibited more sensitive mechanical relaxation responses (i.e., increasing amplitude and speed of the drop in peak load). Additionally, the cord became stiffer (i.e., increasing elastic modulus) and softer (i.e., decreasing elastic modulus) at a higher velocity and larger contact stress area, respectively. These findings will improve our understanding of the real-time complex biomechanics involved in traumatic spinal cord injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.