AimsTo predict the vault and the EVO-implantable collamer lens (ICL) size by artificial intelligence (AI) and big data analytics.MethodsSix thousand two hundred and ninety-seven eyes implanted with an ICL from 3536 patients were included. The vault values were measured by the anterior segment analyzer (Pentacam HR). Permutation importance and Impurity-based feature importance are used to investigate the importance between the vault and input parameters. Regression models and classification models are applied to predict the vault. The ICL size is set as the target of the prediction, and the vault and the other input features are set as the new inputs for the ICL size prediction. Data were collected from 2015 to 2020. Random Forest, Gradient Boosting and XGBoost were demonstrated satisfying accuracy and mean area under the curve (AUC) scores in vault predicting and ICL sizing.ResultsIn the prediction of the vault, the Random Forest has the best results in the regression model (R2=0.315), then follows the Gradient Boosting (R2=0.291) and XGBoost (R2=0.285). The maximum classification accuracy is 0.828 in Random Forest, and the mean AUC is 0.765. The Random Forest predicts the ICL size with an accuracy of 82.2% and the Gradient Boosting and XGBoost, which are also compatible with 81.5% and 81.8% accuracy, respectively.ConclusionsRandom Forest, Gradient Boosting and XGBoost models are applicable for vault predicting and ICL sizing. AI may assist ophthalmologists in improving ICL surgery safety, designing surgical strategies, and predicting clinical outcomes.
BackgroundThyroid-associated ophthalmopathy (TAO) is one of the most common orbital diseases that seriously threatens visual function and significantly affects patients’ appearances, rendering them unable to work. This study established an intelligent diagnostic system for TAO based on facial images.MethodsPatient images and data were obtained from medical records of patients with TAO who visited Shanghai Changzheng Hospital from 2013 to 2018. Eyelid retraction, ocular dyskinesia, conjunctival congestion, and other signs were noted on the images. Patients were classified according to the types, stages, and grades of TAO based on the diagnostic criteria. The diagnostic system consisted of multiple task-specific models.ResultsThe intelligent diagnostic system accurately diagnosed TAO in three stages. The built-in models pre-processed the facial images and diagnosed multiple TAO signs, with average areas under the receiver operating characteristic curves exceeding 0.85 (F1 score >0.80).ConclusionThe intelligent diagnostic system introduced in this study accurately identified several common signs of TAO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.