Appropriate window solutions are decisive for the design of 'nearly zero-energy' buildings with healthy and comfortable indoor environment. This paper focuses on the relationship between size, orientation and glazing properties of façade windows for different side-lit room geometries in Danish 'nearly zero-energy' houses. The effect of these parameters on space heating demand, daylighting and thermal environment is evaluated by means of EnergyPlus and DAYSIM and presented in charts illustrating how combinations of design parameters with minimum space heating demand can be selected within a solution space defined by targets for daylighting and thermal comfort. In contrast with existing guidelines, the results show an upper limit for energy savings and utilisation of solar gains in south-oriented rooms. Instead, low U-values are needed in both north-and south oriented rooms before large window areas lead to reductions in space heating demand. Furthermore, windows in south-oriented rooms have to be carefully designed to prevent overheating. Design options for prevention of overheating, however, correspond well with options for low space heating demand. Glazings with solar control coating are therefore obvious alternatives to dynamic solar shadings. Regarding room geometry, deep or narrow southoriented rooms show difficulties in reaching sufficient daylight levels without overheating.
Internal insulation is used in many heritage buildings to ensure a better indoor environment and reduce energy use. This article describes measurement results from installing an internal insulation system in a Danish multi-story building. The internal insulation system consists of a fully glued vapour tight insulated plasterboard. To reduce the risk for wood decay and mould growth at the wooden beam ends in the floor construction, a 100-200 mm uninsulated gap was left above and below the floor construction. Measurements include the effect of orientation, degree of façade repair and influence of indoor moisture content. Results show in general acceptable hygrothermal conditions behind the insulation system. However, a gradual increase in relative humidity at sun-exposed walls was registered due to ‘summer condensation’. The degree of surface repair also showed an influence on relative humidity levels during this period. At the uninsulated gap above the floor, a higher moisture content indoor resulted in a higher relative humidity, though without exceeding the threshold for mould growth. However, a large temperature range was registered. The influence of the uninsulated gap on reducing the risk of wood decay and mould growth at the beam ends could therefore not unambiguously be confirmed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.