A high-precision optical probe based on the principle of focusing-range detection is developed in this research. The probe adopted for use was directly taken from the pickup head of a CD player. Because its principle is similar to that of the autofocusing probe, the characteristics of each component of the head were investigated and its conversion into a focusing probe was attempted. The S-curve within the focusing range can be analysed, revealing the linear relationship between the normalized focus-error signal (FES) and the measured distance. The system accuracy of the probe was found. Within the measurement range of 10 µm the linearity error was about 1%, the standard deviation was about 34 nm and the frequency response was about 8 kHz. Some practical applications were carried out, namely profile measurements of a step height, a CD surface and a silicon-wafer grating. All results were highly consistent with the nominal values.
An electro-optic modulator applied to a carrier frequency is used to measure the retardation of a wave plate. This method is not only suitable for any wave plate but also can be operated in real time.
The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fabry-Perot interferometers, which feature common optical paths, are insensitive to environmental disturbances. That would be advantageous for precision displacement measurements under ordinary environmental conditions. To verify and analyze this influence, displacement measurements with the two types of interferometers, i.e., a self-fabricated Fabry-Perot interferometer and a commercial Michelson interferometer, have been performed and compared under various environmental disturbance scenarios. Under several test conditions, the self-fabricated Fabry-Perot interferometer was obviously less sensitive to environmental disturbances than a commercial Michelson interferometer. Experimental results have shown that induced errors from environmental disturbances in a Fabry-Perot interferometer are one fifth of those in a Michelson interferometer. This has proved that an interferometer with the common optical path structure will be much more independent of environmental disturbances than those with a non-common optical path structure. It would be beneficial for the solution of interferometers utilized for precision displacement measurements in ordinary measurement environments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.