Needle-shaped beams (NBs) featuring a long depth-of-focus (DOF) can drastically improve the resolution of microscopy systems. However, thus far, the implementation of a specific NB has been onerous due to the lack of a common, flexible generation method. Here we develop a spatially multiplexed phase pattern that creates many axially closely spaced foci as a universal platform for customizing various NBs, allowing flexible manipulations of beam length and diameter, uniform axial intensity, and sub-diffraction-limit beams. NBs designed via this method successfully extended the DOF of our optical coherence tomography (OCT) system. It revealed clear individual epidermal cells of the entire human epidermis, fine structures of human dermal-epidermal junction in a large depth range, and a high-resolution dynamic heartbeat of alive Drosophila larvae.
Cellular-resolution optical coherence tomography (OCT) is a powerful tool offering noninvasive histologylike imaging. However, like other optical microscopy tools, a high numerical aperture (N.A.) lens is required to generate a tight focus, generating a narrow depth of field, which necessitates dynamic focusing and limiting the imaging speed. To overcome this limitation, we developed a metasurface platform that generates multiple axial foci, which multiplies the volumetric OCT imaging speed by offering several focal planes. This platform offers accurate and flexible control over the number, positions, and intensities of axial foci generated. Allglass metasurface optical elements 8 mm in diameter are fabricated from fused-silica wafers and implemented into our scanning OCT system. With a constant lateral resolution of 1.1 μm over all depths, the multifocal OCT triples the volumetric acquisition speed for dermatological imaging, while still clearly revealing features of stratum corneum, epidermal cells, and dermal-epidermal junctions and offering morphological information as diagnostic criteria for basal cell carcinoma. The imaging speed can be further improved in a sparse sample, e.g., 7-fold with a seven-foci beam. In summary, this work demonstrates the concept of metasurface-based multifocal OCT for rapid virtual biopsy, further providing insights for developing rapid volumetric imaging systems with high resolution and compact volume.
Optical imaging techniques provide low-cost, non-radiative images with high spatiotemporal resolution, making them advantageous for long-term dynamic observation of blood perfusion in stroke research and other brain studies compared to non-optical methods. However, high-resolution imaging in optical microscopy fundamentally requires a tight optical focus, and thus a limited depth of field (DOF). Consequently, large-scale, non-stitched, high-resolution images of curved surfaces, like brains, are difficult to acquire without z-axis scanning. To overcome this limitation, we developed a needle-shaped beam optical coherence tomography angiography (NB-OCTA) system, and for the first time, achieved a volumetric resolution of less than 8 µm in a non-stitched volume space of 6.4 mm × 4 mm × 620 µm in vivo. This system captures the distribution of blood vessels at 3.4-times larger depths than normal OCTA equipped with a Gaussian beam (GB-OCTA). We then employed NB-OCTA to perform long-term observation of cortical blood perfusion after stroke, and quantitatively analyzed the vessel area density (VAD) and the diameters of representative vessels in different regions over 10 days, revealing different spatiotemporal dynamics in the acute, sub-acute and chronic phase of post-ischemic revascularization. Benefiting from our NB-OCTA, we revealed that the recovery process is not only the result of spontaneous reperfusion, but also the formation of new vessels. This study provides visual and mechanistic insights into strokes and helps to deepen our understanding of the spontaneous response of brain after stroke.
The sense of touch is critical to dexterous use of the hands and thus an essential component to efforts to restore hand function after amputation or paralysis. Prosthetic systems have focused on wearable tactile sensors. But wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient’s own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive force sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop testing, and ex vivo testing in a primate hand. The sensor implanted in the fingertip accurately measured skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.