It appears that iron supplementation in non-anaemic pregnant women may not be beneficial, as we have observed the adverse effects with a prescribed dose of 45 mg/day. This may warrant the consideration of an individualized approach for antenatal iron supplementation, especially in non-anaemic women.
Obesity indicators, especially waist-to-height ratio due to its ease of measurement, can be useful initial screening tools for risk of high blood pressure in urban Indian school children.
BackgroundEarly diagnosis of shock is a predetermining factor for a good prognosis in intensive care. An elevated central venous to arterial PCO2 difference (∆PCO2) over 0.8 kPa (6 mm Hg) is indicative of low blood flow states. Disturbances around the time of blood sampling could result in inaccurate calculations of ∆PCO2, thereby misrepresenting the patient status. This study aimed to determine the influences of acute changes in ventilation on ∆PCO2 and understand its clinical implications.MethodsTo investigate the isolated effects of changes in ventilation on ∆PCO2, eight pigs were studied in a prospective observational cohort. Arterial and central venous catheters were inserted following anaesthetisation. Baseline ventilator settings were titrated to achieve an EtCO2 of 5±0.5 kPa (VT = 8 mL/kg, Freq = 14 ± 2/min). Blood was sampled simultaneously from both catheters at baseline and 30, 60, 90, 120, 180 and 240 s after a change in ventilation. Pigs were subjected to both hyperventilation and hypoventilation, wherein the respiratory frequency was doubled or halved from baseline. ∆PCO2 changes from baseline were analysed using repeated measures ANOVA with post-hoc analysis using Bonferroni’s correction.Results∆PCO2 at baseline for all pigs was 0.76±0.29 kPa (5.7±2.2 mm Hg). Following hyperventilation, there was a rapid increase in the ∆PCO2, increasing maximally to 1.35±0.29 kPa (10.1±2.2 mm Hg). A corresponding decrease in the ∆PCO2 was seen following hypoventilation, decreasing maximally to 0.23±0.31 kPa (1.7±2.3 mm Hg). These changes were statistically significant from baseline 30 s after the change in ventilation.ConclusionDisturbances around the time of blood sampling can rapidly affect the PCO2, leading to inaccurate calculations of the ∆PCO2, resulting in misinterpretation of patient status. Care should be taken when interpreting blood gases, if there is doubt as to the presence of acute and transient changes in ventilation.
Objective: Routine high-dose Fe supplementation in non-anaemic pregnant women may induce oxidative stress and eventually affect birth outcomes. The aim of the present study was to measure oxidative stress markers in pregnant women with low/normal and high Hb values in trimester 1 (Hb 1 ) and to relate these to birth weight. Design: A cross-sectional study where selected oxidative stress markers were analysed in both maternal (trimester 1; T1) and cord blood samples and correlated with birth weight. Setting: A tertiary hospital in urban South India. Subjects: One hundred women were chosen based on their Hb 1 values (forty women with low/normal Hb 1 (<110 g/l) and sixty women with high Hb 1 (≥120 g/l)). Results: In T1, women with high Hb 1 values were found to have lower paraoxonase-1 (PON-1) activity (424·7 (SD 163·7) v. 532·9 (SD 144·7) pmol p-nitrophenol formed/min per ml plasma, P = 0·002) and higher lipid peroxides compared with women with low/normal Hb 1 . Routine supplementation of Fe to these women resulted in persistent lower PON-1 activity in cord blood (P = 0·02) and directionally lower (P = 0·142) birth weights. Furthermore, women with high Hb 1 who delivered low-birth-weight babies were observed to have lowest PON-1 activity in T1. No changes were observed in other markers (myeloperoxidase activity and total antioxidant levels). Conclusions: Routine Fe supplementation in pregnant women with high Hb 1 associated with increased oxidative stress, as reflected by low PON-1 activity in T1, could potentially lead to deleterious effects on birth weight.
Background ABGs are performed in acute conditions as the reference method for assessing the acid-base status of blood. Hyperventilation and breath-holding are common ventilatory changes that occur around the time of sampling, rapidly altering the ‘true’ status of the blood. This is particularly relevant in emergency medicine patients without permanent arterial catheters, where the pain and anxiety of arterial punctures can cause ventilatory changes. This study aimed to determine whether peripheral venous values could be a more reliable measure of blood gases following acute changes in ventilation. Methods To allow for characterisation of ventilatory changes typical of acutely ill patients, but without the confounding influence of perfusion or metabolic disturbances, 30 patients scheduled for elective surgery were studied in a prospective observational study. Following anaesthesia, and before the start of the surgery, ventilator settings were altered to achieve a + 100% or − 60% change in alveolar ventilation (‘hyper-’ or ‘hypoventilation’), changes consistent with the anticipation of a painful arterial puncture commonly encountered in the emergency room. Blood samples were drawn simultaneously from indwelling arterial and peripheral venous catheters at baseline, and at 15, 30, 45, 60, 90 and 120 s following the ventilatory change. Comparisons between the timed arterial (or venous) samples were done using repeated-measures ANOVA, with post-hoc analysis using Bonferroni’s correction. Results Arterial blood pH and PCO2 changed rapidly within the first 15–30s after both hyper- and hypoventilation, plateauing at around 60s (∆pH = ±0.036 and ∆PCO2 = ±0.64 kPa (4.7 mmHg), respectively), with peripheral venous values remaining relatively constant until 60s, and changing minimally thereafter. Mean arterial changes were significantly different at 30s (P < 0.001) when compared to baseline, in response to both hyper- and hypoventilation. Conclusion This study has shown that substantial differences in arterial and peripheral venous acid-base status can be due to acute changes in ventilation, commonly seen in the ER over the 30s necessary to sample arterial blood. If changes are transient, peripheral venous blood may provide a more reliable description of acid-base status.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.