Summary: This paper proposes a 1/f noise optimized correlated
multiple sampling (NOCMS) technique based on differentiated sampling
weights for CMOS image sensor. Transfer functions of standard CMS and
NOCMS for analyzing the suppression effect of random noise respectively
are derived based on the Fourier Transform theory. NOCMS shows a
dramatic advantage in the suppression of 1/f noise. For implementing
NOCMS, the ramp generator provides multiple sets of ramps with different
slopes to quantize the reset and signal voltages. Sampling weights are
increased with the decrease of ramp slopes. The last reset and first
signal values are weighted more due to their potentially higher
correlations. Simulation results under 110nm CMOS technology illustrate
that the ADC achieves DNL of −0.80/+0.70LSB and INL of −0.70/+0.90LSB
after the NOCMS operation. The input-referred random noise is 142.9µV
under standard CMS and 120.9µV
under NOCMS when the number of samples equals 8. The noise reduction
effect is improved by 15%. NOCMS makes it possible to further reduce
1/f noise of CMOS image sensor.
SummaryCorrelated multiple sampling (CMS) technique is often used to reduce random noise in complementary metal oxide semiconductor (CMOS) image sensor, but as the number of samples increases, the suppression of 1/f noise by standard CMS based on averaging sampling gradually decreases. Therefore, in this paper, a 1/f noise optimized correlated multiple sampling (NOCMS) technique based on differentiated sampling weights is proposed. Transfer functions of standard CMS and NOCMS for analyzing the suppression effect of random noise respectively are derived based on the Fourier transform theory. And NOCMS shows a dramatic advantage in the suppression of 1/f noise. In addition, a circuit structure based on single‐slope analog‐to‐digital converter (SSADC) for implementing NOCMS is suggested. Ramp generator provides multiple sets of ramps with different slopes to quantify the reset and signal voltages of pixel output. Sampling weights are increased with the decrease of ramp slopes. The last reset and first signal values are weighted more due to their potentially higher correlations which highlights the principle of assigning weights. Simulation results under 110 nm CMOS technology illustrate that the input‐referred random noise is 142.9
V
under standard CMS and 120.9
V
under NOCMS when the number of samples equals 8. The noise reduction effect is improved by 15%. NOCMS makes it possible to further reduce 1/f noise of CMOS image sensor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.