Micromixing injection combustion is an effective low-NO x combustion technology, but a high wall temperature near the burner nozzle exit is detrimental to the nozzle and will affect burner safety in this technology. In this paper, CO 2 dilution and micromixing injection combustion were combined to try to reduce NO x emissions and lower the wall temperature near the nozzle exit. Several experimental results for flames with a thermal power of 20 kW are reported as follows: the wall temperature near the nozzle can be lowered effectively by CO 2 dilution combustion. The more diluent there is, the lower the wall temperature near the nozzle exit can be. Both low NO x and CO emissions can be achieved at the same time. By adjusting the combustion parameters, NO x emissions can be reduced to 2 ppm (15% O 2 ), and the CO emissions can be reduced to 3 ppm (15% O 2 ). In terms of the relationship between NO x and CO emissions and diluents, more diluents can lead to lower NO x emissions but can increase the CO emission. The hydrocarbon ratio of the diluted fuel can affect the wall temperature and the NO x and CO emissions. When the C/H ratio is high, the wall temperature of the nozzle is high and the NO x and the CO emissions increase.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.