Reprocessing of used N95 respirators may ameliorate supply chain constraints during the COVID-19 pandemic and provide a higher filtration crisis alternative. The FDA Medical Countermeasures Initiative previously funded a study of HP vapor decontamination of respirators using a Clarus C system (Bioquell, Horsham, PA) which normally is used to fumigate hospital rooms. The process preserved respirator function, but it is unknown if HP vapor would be virucidal since respirators have porous fabric that may harbor virus.
We evaluated the virucidal activity of HP vapor using a BQ-50 system (Bioquell, Horsham, PA) after inoculating 3M 1870 N95 respirators (3M, St. Paul, MN) with 3 aerosolized bacteriophage that are a reasonable proxy for SARS-CoV-2. Inoculation resulted in contamination of the respirator with 9.87e4 plaque forming units (PFU) of phage phi-6, 4.17e7 PFU of phage T7 and 1.35e7 PFU of phage T1. Respirators were reprocessed with BQ-50 with a long aeration phase to reduce HP vapors. Virucidal activity was measured by a standard plaquing assay prior to and after sterilization. A single HP vapor cycle resulted in complete eradication of phage from masks (limit of detection 10 PFU, lower than the infectious dose of the majority of respiratory viral pathogens). After 5 cycles, the respirators appeared similar to new with no deformity.
Use of a Bioquell machine can be scaled to permit simultaneous sterilization of a large number of used but otherwise intact respirators. HP vapor reprocessing may ease shortages and provide a higher filtration crisis alternative to non-NIOSH masks.
Transcatheter aortic valve implantation is increasingly being used to treat severe aortic stenosis in patients with high operative risk. In an aging population the incidence of aortic stenosis is rising, and increasing numbers of elderly patients are undergoing aortic valve replacement with bioprosthetic valves. Therefore, there is a corresponding increase in prosthetic degeneration. This presents cardiologists with a cohort of patients for whom the risk of re-do aortic valve surgery is prohibitive. We present the first series of such patients with degenerative bioprosthetic stenosis or regurgitation successfully treated with CoreValve (Medtronic, Luxembourg) implantation.
Patients undergoing TAVI have an immediate postprocedural risk of regurgitation of 86%. In the majority of cases the degree of paravalvular CoreValve regurgitation is mild, and remains stable in 70% of patients during medium term follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.