Currently, the availability of a wide variety of universal adhesives makes it difficult for clinicians to choose the correct system for specific bonding situations to dentin substrate. This study aimed to determine whether there are any alternative techniques or additional strategies available to enhance the bond strength of universal adhesives to dentin through a systematic review and meta-analysis. Two reviewers executed a literature search up to September 2020 in four electronic databases: PubMed, ISI Web of Science, Scopus, and EMBASE. Only in vitro studies that reported the dentin bond strength of universal adhesives using additional strategies were included. An analysis was carried out using Review Manager Software version 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic. A total of 5671 potentially relevant studies were identified. After title and abstract examination, 74 studies remained in systematic review. From these, a total of 61 studies were included in the meta-analysis. The bond strength of universal adhesives to dentin was improved by the use of one of the following techniques: Previous application of matrix metalloproteinases (MMP) inhibitors (p < 0.001), prolonged application time (p = 0.007), scrubbing technique (p < 0.001), selective dentin etching (p < 0.001), non-atmospheric plasma (p = 0.01), ethanol-wet bonding (p < 0.01), prolonged blowing time (p = 0.02), multiple layer application (p = 0.005), prolonged curing time (p = 0.006), and hydrophobic layer coating (p < 0.001). On the other hand, the use of a shortened application time (p = 0.006), and dentin desensitizers (p = 0.01) impaired the bond strength of universal adhesives to dentin. Most of the analyses performed showed a high heterogenicity. The in vitro evidence suggests that the application of universal adhesives using some alternative techniques or additional strategies may be beneficial for improving their bonding performance to dentin. This research received no external funding. Considering that this systematic review was carried out only with in vitro studies, registration was not performed.
There are a number of potential implications for the field of Alzheimer’s disease (AD) stemming from the global spread of “SARS-COV-2”. Many studies that were conducted by Cleveland Clinic researchers identified a link between COVID-19 infection and brain abnormalities seen in people with AD. This article explains the association between COVID-19 and AD and how people with AD are affected by COVID-19, whether directly or indirectly. First, this article begins by explaining AD and its types, then giving an overview about COVID-19, its symptoms and the associated complications. Then, direct and indirect consequences of COVID-19 on people experiencing AD are discussed briefly. Some management strategies are recommended at the end of this article in addition to a future perspective on this topic. This article concludes by summarizing the main points mentioned about the association between COVID-19 and AD.
Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to delayed dentin sealing (DDS), a technique in which hybridization is performed following the provisional phase and just before the indirect restoration luting procedure. This study aimed to compare the bond strength of restorations to dentin of the IDS and the DDS techniques throughout a systematic review and meta-analysis. The following PICOS framework was used: population, indirect restorations; intervention, IDS; control, DDS; outcomes, bond strength; and study design, in vitro studies. PubMed (MedLine), The Cochrane Library, ISI Web of Science, Scielo, Scopus, and Embase were screened up to January 2022 by two reviewers (L.H. and R.B.). In vitro papers studying the bond strength to human dentin of the IDS technique compared to the DDS technique were considered. Meta-analyses were carried out by using a software program (Review Manager v5.4.1; The Cochrane Collaboration). Comparisons were made by considering the adhesive used for bonding (two-step etch-and-rinse, three step etch-and-rinse, one-step self-etch, two-step self-etch, and universal adhesives). A total of 3717 papers were retrieved in all databases. After full-text assessment, 22 potentially eligible studies were examined for qualitative analysis, leaving a total of 21 articles for the meta-analysis. For the immediate bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p < 0.001). Taking into account the subgroup analysis, it seems that the use of the IDS technique with a two-step etch-and-rinse or a one-step self-etch adhesive system does not represent any advantage over the DDS technique (p = 0.07, p = 0.15). On the other hand, for the aged bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p = 0.001). The subgroups analysis shows that this improvement is observed only when a three-step etch-and-rinse adhesive system (p < 0.001) or when a combination of an adhesive system plus a layer of flowable resin (p = 0.01) is used. The in vitro evidence suggests that the use of the IDS technique improves the bond strength of dentin to resin-based restorations regardless of the adhesive strategy used. The use of a three-step etch-and-rinse adhesive system or the combination of an adhesive system plus a layer of flowable resin seems to considerably enhance the bond strength in the long term.
Purpose: To evaluate the fracture resistance and failure modes of endodontically treated mandibular molars restored with different designs of inlays, onlays and endocrowns. Materials and Methods: Extracted mandibular third molars (n = 180) were used. An access cavity was prepared on the occlusal surface of each tooth and the roots were obturated with gutta percha. All specimens were randomly divided into 6 groups (n = 30/group) according to the cavity design and the restoration material used. C: control group without access cavity preparation. IE: MOD inlay preparation with Ev-erX Posterior (GC Europe) in the pulp chamber. IG: MOD inlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. OE: onlay preparation with EverX Posterior (GC Europe) in the pulp chamber. OG: onlay preparation with G-aenial Universal Flo (GC America) in the pulp chamber. EC: endocrown with an empty pulp chamber. All restorations were fabricated with CAD/CAM system using CERASMART ® (GC Dental products Europe, Belgium) CAD/CAM blocks. Specimens were thermal-cycled and were subjected to a compressive load applied at 30°a ngle relative to the long axis of the tooth with a universal testing machine. Results were statistically analyzed by ANOVA followed by Tukey post hoc tests. Chi-square test and Fisher Exact tests were used for the comparisons among groups.Results: The mean fracture strength was significantly different between the groups (p < 0.001); it was significantly highest for intact teeth, followed by endocrowns (p = 0.021). The strength was significantly lower for inlays (with G-aenial Universal Flo and EverX Posterior), intermediate for onlays with EverX Posterior followed by onlays with G-aenial Universal Flo. Conclusions: Endocrowns exhibited higher fracture resistance than other tested composite resin groups. Endocrowns and onlays showed a more favorable failure mode than inlay restorations.
Since color matching is considered a subjective procedure, accurate shade choice is often the most challenging stage of recreating the natural appearance of teeth. Furthermore, accurate determination of tooth color is imperative for the final outcome of dental restorations. The purpose of this research is to assess the accuracy of color match between diverse shade selection methods throughout a systematic review and meta-analysis. Two independent investigators (L.H. and R.B.) screened the literature in five electronic databases. Randomized controlled trials or in vitro papers studying the effect of using either digital shade selection or visual shade selection on the accuracy of color match were included. A total of 13 manuscripts comprised the meta-analysis. Color difference (ΔE) between restorations where the shade matching was performed by the conventional method was greater than those where the shade matching was performed by computerized methods (p = 0.007). According to the subgroup analysis, only the use of digital photographs for shade matching showed a reduction in the (ΔE) (p < 0.0001), while the use of a spectrophotometer has no advantages over the use of visual shade guide tabs (p = 0.57). On the other hand, global analysis showed that incorrect shade matching was higher when the conventional method using shade guide tabs was used (p < 0.001), irrespective of whether a spectrophotometer or a digital camera was used (p < 0.001). This study concluded that the use of digital photography and spectrophotometric measurements led to fewer color differences and less incorrect shade matching than conventional methods using color shade tabs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.