We evaluated a novel, portable breath sampler/CO-quantifying instrument [Baby's Breath Carbon Monoxide Analyzer (BB); Natus Medical], developed for use at the bedside or with gas samples collected into bags. Bench tests demonstrated that the CO measurements were linear, accurate, and precise when compared with gas chromatography (GC) results. In vivo tests (n = 30) performed with adults showed excellent correlation between end-tidal breath CO measurements (ETCO) corrected for inhaled CO (ETCOc) as determined by BB and GC. Breath sampling efficiency was 96%. ETCOc measurements and blood carboxyhemoglobin fractions (% of total hemoglobin) corrected for inhaled CO (COHbc) correlated strongly: COHbc = 0.25 ETCOc--0.01 microL/L CO (r2 = 0.97, Sy/x = 0.47, SE slope = 0.01, n = 30). The imprecision, assessed by the mean of the population's CV for triplicate determinations, was 11%. Measurements with healthy and hemolytic term newborns showed that ETCOc values of > 3 microL/L correlated with known hemolytic conditions. We conclude that this instrument is clinically reliable and can be used to noninvasively measure ETCO in neonates and adults.
This report describes a case of parenteral nutrition hypersensitivity in a 37 weeks' gestation infant with congenital diaphragmatic hernia complicated by bowel necrosis and functional short bowel syndrome. The patient developed a rash with subsequent urticaria beginning on the 50th day of life. The reactions were confirmed with a positive rechallenge. After the amino acid solution was replaced with a non-bisulfite-containing product, the infant was able to continue to receive nutrition support through parenteral nutrition without recurrence of symptoms. It is speculated that the bisulfite additive in the amino acid solution may have interacted with the lipid emulsion to sensitize the patient.
Antenatal cocaine exposure is associated with elevated cord blood CK, and possibly with elevated cord blood myoglobin. Additional studies, using larger study populations and more sensitive methods of detecting antenatal cocaine exposure, along with detailed follow-up examination of infants, are indicated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.