The objective of this work was to develop a sample preparation procedure for determination of the carbohydrate profiles in commercial juice samples by three principally different analytical methods: capillary electrophoresis (CE) with indirect detection, high-performance liquid chromatography (HPLC), and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The preparation and purification of juice samples prior to analysis is described. The method using Carrez reagents was found to be an efficient preparation tool for all three methods. The addition of Carrez reagents to the samples for mass analysis improved the quality of the mass spectra of oligosaccharides. The amounts of glucose, fructose, and sucrose as major carbohydrates in fruit juices measured by CE using a simple instrument are in good agreement with the HPLC values and the data declared by the producers of the juices. The results from both methods are critically evaluated and their impact for studies of authenticity is discussed. The decrease of sucrose amount during the storage of samples was explained by acid hydrolysis of this disaccharide.
The methodology and instrumentation for fast denaturing electrophoresis in short capillaries was developed and exemplified by detection of short tandem repeat polymorphism in the endothelin 1 gene. The resolution of two nucleotides, which is required for the detection of a dinucleotide repeat polymorphism, was achieved in a capillary of an effective length of 2.5 cm at a temperature of 600C and an electric field strength of 600 V/cm in 42 s. Thus, the use of denaturing electrophoresis in short capillaries with laser-induced fluorescence detection resulted in a reduction of analysis time by a factor of 200 when compared to the conventional slab gel electrophoresis. The developed methodology and instrumentation is advantageous for an implementation in clinical diagnostics and genetic population screening where fast analytical instrumentation amenable to automation is of paramount importance.
The methodology and instrumentation for fast denaturing electrophoresis in short capillaries was developed and exemplified by detection of short tandem repeat polymorphism in the endothelin 1 gene. The resolution of two nucleotides, which is required for the detection of a dinucleotide repeat polymorphism, was achieved in a capillary of an effective length of 2.5 cm at a temperature of 60°C and an electric field strength of 600 V/cm in 42 s. Thus, the use of denaturing electrophoresis in short capillaries with laser‐induced fluorescence detection resulted in a reduction of analysis time by a factor of 200 when compared to the conventional slab gel electrophoresis. The developed methodology and instrumentation is advantageous for an implementation in clinical diagnostics and genetic population screening where fast analytical instrumentation amenable to automation is of paramount importance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.