Objective Lithium remains an important treatment for mood disorders but is associated with kidney disease. Nephrogenic diabetes insipidus (NDI) is associated with up to 3‐fold risk of incident chronic kidney disease among lithium users. There are limited randomized controlled trials (RCT) for treatments of lithium‐induced NDI, and existing therapies can be poorly tolerated. Therefore, novel treatments are needed for lithium‐induced NDI. Method We conducted a 12‐week double‐blind pilot RCT to assess the feasibility and efficacy of 20 mg/d atorvastatin vs placebo in the treatment of NDI in chronic lithium users. Patients, recruited between September 2017 and October 2018, were aged 18 to 85, currently on a stable dose of lithium, and determined to have NDI. Results Urinary osmolality (UOsm) at 12 weeks adjusted for baseline was not statistically different between groups (+39.6 mOsm/kg [95% CI, −35.3, 114.5] in atorvastatin compared to placebo groups). Secondary outcomes of fluid intake and aquaporin‐2 excretions at 12 weeks adjusted for baseline were −0.13 L [95% CI, −0.54, 0.28] and 98.68 [95% CI, −190.34, 387.70], respectively. A moderate effect size was observed for improvements in baseline UOsm by ≥100 mOsm/kg at 12 weeks in patients who received atorvastatin compared to placebo (38.45% (10/26) vs 22.58% (7/31); Cohen's d = 0.66). Conclusion Among lithium users with NDI, atorvastatin 20 mg/d did not significantly improve urinary osmolality compared to placebo over a 12‐week period. Larger confirmatory trials with longer follow‐up periods may help to further assess the effects of statins on NDI, especially within patients with more severe NDI.
Accumulation of uremic toxins may lead to the life-threatening condition “uremic syndrome” in patients with advanced chronic kidney disease (CKD) requiring renal replacement therapy. Clinical evaluation of proximal tubular secretion of organic cations (OC), of which some are uremic toxins, is desired, but difficult. The biomedical knowledge on OC secretion and cellular transport partly relies on studies using the fluorescent tracer 4-dimethylaminostyryl)-N-methylpyridinium (ASP+), which has been used in many studies of renal excretion mechanisms of organic ions and which could be a candidate as a PET tracer. This study is aimed at expanding the knowledge of the tracer characteristics of ASP+ by recording the distribution and intensity of ASP+ signals in vivo both by fluorescence and by positron emission tomography (PET) imaging and at investigating if the fluorescence signal of ASP+ is influenced by the presence of albumin. Two-photon in vivo microscopy of male Münich Wistar Frömter rats showed that a bolus injection of ASP+ conferred a fluorescence signal to the blood plasma lasting for about 30 minutes. In the renal proximal tubule, the bolus resulted in a complex pattern of fluorescence including a rapid and strong transient signal at the brush border, a very low signal in the luminal fluid, and a slow transient intracellular signal. PET imaging using 11C-labelled ASP+ showed accumulation in the liver, heart, and kidney. Fluorescence emission spectra recorded in vitro of ASP+ alone and in the presence of albumin using both 1-photon excitation and two-photon excitation showed that albumin strongly enhance the emission from ASP+ and induce a shift of the emission maximum from 600 to 570 nm. Conclusion. The renal pattern of fluorescence observed from ASP+ in vivo is likely affected by the local concentration of albumin, and quantification of ASP+ fluorescent signals in vivo cannot be directly translated to ASP+ concentrations.
Renal micropuncture, which requires the direct access to the renal tubules, has for long time been the technique of choice to measure the single nephron glomerular filtration rate (SNGFR) in animal models. This approach is challenging by virtue of complex animal preparation and numerous technically difficult steps. The introduction of intravital multiphoton microscopy (MPM) offers another approach to the measure of the SNGFR by mean of the high laser-tissue penetration and the optical sectioning capacity. Previous MPM studies measuring SNGFR in vivo relied on fast full-frame acquisition during the filtration process obtainable with high performance resonant scanners. In this study, we describe an innovative linescan–based MPM method. The new method can discriminate SNGFR variations both in conditions of low and high glomerular filtration, and shows results comparable to conventional micropuncture both for rats and mice. Moreover, this novel approach has improved spatial and time resolution and is faster than previous methods, thus enabling the investigation of SNGFR from more tubules and improving options for data-analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.