Purpose To demonstrate axonal loss in the retinal nerve fiber layer (RNFL) of patients with Parkinson's disease (PD) and to evaluate the ability of Fourier-domain optical coherence tomography (OCT) to detect RNFL degeneration and retinal thinning in these patients. Methods PD patients (n ¼ 100) and healthy subjects (n ¼ 100) were included in the study and underwent visual acuity, color vision, and OCT examinations using two nextgeneration Fourier-domain devices (Spectralis and Cirrus). Differences in the RNFL thicknesses were compared between patients and controls. Results RNFL thicknesses were significantly reduced in PD patients compared with healthy subjects, especially those obtained using the Spectralis OCT, in the inferotemporal quadrant (155.6 ± 16.5 lm in healthy eyes vs 142.1 ± 24.9 lm in patients, P ¼ 0.040) and in the superotemporal quadrant (142.6±20.9 lm in healthy eyes vs 132.77±18.6 lm in PD patients, P ¼ 0.046). Significant differences were observed between controls and patients in relation to mean macular thickness (P ¼ 0.031), foveal thickness (P ¼ 0.030), and inferior outer thickness (P ¼ 0.019). Conclusion PD is associated with RNFL loss and retinal thinning, which is detectable by Fourier-domain OCT measurements.
ABSTRACT.Purpose: To evaluate the thickness of the 10 retinal layers of patients with Alzheimer's disease (AD) using a new segmentation technology of the Spectralis optical coherence tomography (OCT) and to determine whether the thickness of specific layers predicts neurodegeneration or AD severity. Methods: Patients with AD (n = 150) and age-matched healthy controls (n = 75) were analysed using the segmentation application prototype to automatically segment all retinal layers in a macular scan. Thicknesses of each layer were compared between patients with AD and controls, and between patients with disease durations of less than or at least 3 years. Associations between retinal layer thicknesses, disease duration and AD severity were evaluated. Results: Patients with AD had reduced thickness in the retinal nerve fibre, ganglion cell, inner plexiform and outer nuclear layers (p < 0.05). The inner retinal layers were more affected in patients with long disease duration. Ganglion cell and retinal nerve fibre layer thicknesses were inversely correlated with AD duration and severity. Ganglion cell and inner plexiform layers thicknesses were predictive of axonal damage. Conclusions: The segmentation application revealed ganglion cell and retinal layer atrophy in patients with AD compared with controls, especially in the inner layers of patients with long disease duration. Ganglion cell layer reduction was associated with increased axonal damage and may predict greater disease severity.
Patients with greater damage in the RNFL tend to have lower QOL and more severe PD symptoms. Foveal thicknesses and the PERG N95 component provide good biomarkers for predicting QOL and disease severity.
PurposeThe purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG) not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol.Patients and methodsOf 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy.ResultsAt the month 12 visit, 94.7% of eyes (89/94) in the stent group reported an unmedicated intraocular pressure (IOP) reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98) in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02) at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94) in the iStent inject group and 89.8% of eyes (88/98) in the medical therapy group. Mean (standard deviation) IOP decreases from screening of 8.1 (2.6) mmHg and 7.3 (2.2) mmHg were reported in the iStent inject and medical therapy groups, respectively. A high safety profile was also noted in this study in both the iStent inject and medical therapy groups, as measured by stable best corrected visual acuity, cup-to-disc ratio, and adverse events.ConclusionThese data show that the use of iStent inject is at least as effective as two medications, with the clinical benefit of reducing medication burden and assuring continuous treatment with full compliance to implant therapy as well as having a highly favorable safety profile.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.