The highest total dose absorbed in normal tissue was observed with the use of a robotic radiosurgery system and TomoTherapy. These results demonstrate that the exposure of healthy tissue is a dosimetric factor which differentiates the dose delivery methods.
The aim of this retrospective study was to assess the adverse effects and outcomes of salvage re-irradiation with stereotactic body radiotherapy (sSBRT) for local recurrence of prostate cancer (PCa) after definitive radiotherapy (RT). The study was focused on the adverse effects and prognostic factors for treatment toxicity, followed by an analysis of patterns of failure and survival. Patients treated with sSBRT between 2012 and 2020 at a tertiary institution were included. The exclusion criteria were a primary or salvage radical prostatectomy or a palliative sSBRT dose. Patients with oligorecurrence were eligible if all metastatic lesions were treated locally with curative intent. The Kaplan–Meier method was used to estimate time to grade ≥ 3 toxicity, local control (LC), freedom from distant metastases (FFDM), progression-free survival (PFS), biochemical control (BC) and overall survival (OS). The differences between groups (focal vs. whole-gland sSBRT) were compared using the log-rank test. The Cox proportional hazards model was used to assess prognostic factors for the listed endpoints. A total of 56 patients with a median age of 70.9 years and a median follow-up of 38.6 months were included in the analysis. The majority of them received local sSBRT only (45; 80.4%), while the rest were simultaneously treated for oligometastases (11; 19.6%). Overall, 18 (32.1%) patients experienced any grade ≥ 3 toxicity, including 1 (6.7%) patient who received focal sSBRT, and 17 (41.5%) patients treated with whole-gland sSBRT. The Planning Target Volume (per cc; HR 1.01; 95% CI 1–1.02; p = 0.025) and use of ADT (yes vs. no; HR 0.35; 95%CI 0.13–0.93; p = 0.035) were independent prognostic factors for the risk of grade ≥ 3 toxicity. The estimated rate of grade ≥3 adverse events was significantly higher (7.1% vs. 43.8% at 2 years; p = 0.006), and there was no improvement in the LC (92.9% vs. 85.3% at 2 years; p = 0.759) in patients treated with focal sSBRT compared to whole-gland sSBRT. The 2- and 5-year LC were 87.6% and 47.9%, respectively; the 2- and 5-year FFDM were 72.7% and 42.8%, respectively; and the 2- and 5-year PFS were 67.9% and 28.7%, respectively. The primary pattern of failure was distant metastasis. The sSBRT for local recurrence of PCa after definitive RT was associated with a high risk of severe grade ≥ 3 toxicity, which significantly increased with the volume and extent of re-irradiation.
BackgroundStereotactic Arrhythmia Radioablation (STAR) is an emerging treatment modality for patients with sustained ventricular tachycardia (VT) and refractory to treatment with drugs and radiofrequency catheter ablation (RFA). It is believed that up to 12–17% of patients experience recurrence of VT within 1 year of follow-up; thus, novel therapeutic options are needed. The aim of this article is to present initial experience within a novel treatment modality for VT.Case SummaryTwo patients with a medical history of coronary artery disease and heart failure with reduced left ventricle (LV) ejection fraction, after implantation of cardioverter-defibrillator (ICD) and previous unsuccessful RFAs owing to sustained VT were admitted to the cardiology department due to recurrence of sustained VT episodes. With electroanatomical mapping (EAM), the VT substrate in LV has been confirmed and specified. In order to determine the target volume for radioablation, contrast-enhanced computed tomography was performed and the arrhythmia substrate was contoured using EAM data. Using the Volumetric Modulated Arc Therapy technique and three 6 MeV flattening filter-free photon beam fields, a single dose of 25 Gy was delivered to the target volume structure located in the apex and anterior apical segments of LV in the first patient and in the apex, anterolateral and inferior apical segments of the second patient. In both cases, volumes of the target structures were comparable. Interrogation of the implanted ICD at follow-up visits throughout 6 months after the treatment revealed no VT episodes in the first patient and sudden periprocedural increase in VT burden with a subsequent gradual decrease of ventricular arrhythmia to only two non-sustained episodes at the end of the follow-up period in case of the second patient. A significant reduction in premature ventricular contractions burden was observed compared to the pre-treatment period. No noticeable deterioration in LV function was noted, nor any adverse effects of radiosurgery associated with the implanted device.ConclusionThe early response to STAR can be unpredictable and probably does not reflect the final outcome of irradiation. Close monitoring of patients, especially in the early period after irradiation is crucial to properly handle potentially harmful early reactions to STAR.
Developed dose distribution reconstruction algorithm presents a very useful QA tool. It provides means for 3D dose distribution verification in patient volume and allows to evaluate the influence of actual MLC leaf motion on the dose distribution.
Patients with vetricular tachycardia are usually treated with antiarrhythmic drugs and ablation if the arrhythmia substrate is available for invasive treatment. Despite high efficiency of this treatment there is a significant group of patients who do not benefit from available treatment methods, either because they cannot be applied or do not allow for durable control of the disease. For that reason a novel treatment method, STereotactic Arrhythmia Radioablation (STAR) has been proposed and its safety and efficiency is extensively studied throughout the world. The method is based on irradiation of the arrhythmia substrate identified with electrophysiological examination with high-precision image-guided radiosurgical methods usually used for ablation of malignant tumors. Here we present the protocol of the first Polish study on STAR in patients with intractable ventricular tachycardia (STARVT, NCT04642963), designed to test the safety of the method. Secondary endpoints include measures of the treatment efficiency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.