The EPID based method is efficient and yields more precise data on linear accelerator jaw positioning and reproducibility than previous methods. The results highlight that zero jaw positions are highly reproducible to a level much smaller than the displayed jaw resolution and that there is a need for better methods to calibrate the jaw positioning.
The aim of this study is to present an efficient method to generate imager-specific Monte Carlo ͑MC͒-based dose kernels for amorphous silicon-based electronic portal image device dose prediction and determine the effective backscattering thicknesses for such imagers. EPID field sizedependent responses were measured for five matched Varian accelerators from three institutions with 6 MV beams at the source to detector distance ͑SDD͒ of 105 cm. For two imagers, measurements were made with and without the imager mounted on the robotic supporting arm. Monoenergetic energy deposition kernels with 0-2.5 cm of water backscattering thicknesses were simultaneously computed by MC to a high precision. For each imager, the backscattering thickness required to match measured field size responses was determined. The monoenergetic kernel method was validated by comparing measured and predicted field size responses at 150 cm SDD, 10ϫ 10 cm 2 multileaf collimator ͑MLC͒ sliding window fields created with 5, 10, 20, and 50 mm gaps, and a head-and-neck ͑H&N͒ intensity modulated radiation therapy ͑IMRT͒ patient field. Field size responses for the five different imagers deviated by up to 1.3%. When imagers were removed from the robotic arms, response deviations were reduced to 0.2%. All imager field size responses were captured by using between 1.0 and 1.6 cm backscatter. The predicted field size responses by the imager-specific kernels matched measurements for all involved imagers with the maximal deviation of 0.34%. The maximal deviation between the predicted and measured field size responses at 150 cm SDD is 0.39%. The maximal deviation between the predicted and measured MLC sliding window fields is 0.39%. For the patient field, gamma analysis yielded that 99.0% of the pixels have ␥ Ͻ 1 by the 2%, 2 mm criteria with a 3% dose threshold. Tunable imager-specific kernels can be generated rapidly and accurately in a single MC simulation. The resultant kernels are imager position independent and are able to predict fields with varied incident energy spectra and a H&N IMRT patient field. The proposed adaptive EPID dose kernel method provides the necessary infrastructure to build reliable and accurate portal dosimetry systems.
The long-term stability of three clinical electronic portal imaging devices (EPIDs) was studied to determine if longer times between calibrations can be justified. This would make alternatives to flood-field calibration of EPIDs clinically feasible, allowing for more effective use of EPIDs for dosimetry. Images were acquired monthly for each EPID as part of regular clinical quality assurance over a time period of approximately 3 years. The images were analysed to determine (1) the long-term stability of the EPID positioning system, (2) the dose response of the central pixels and (3) the long term stability of each pixel in the imager. The position of the EPID was found to be very repeatable with variations less than 0.3 pixels (0.27 mm) for all imagers (1 standard deviation). The central axis dose response was found to reliably track ion chamber measurements to better than 0.5%. The mean variation in pixel response (1 standard deviation), averaged over all pixels in the EPID, was found to be at most 0.6% for the three EPIDs studied over the entire period. More than 99% of pixels in each EPID showed less than 1% variation. Since the EPID response was found to be very stable over long periods of time, an annual calibration should be sufficient in most cases. More complex dosimetric calibrations should be clinically feasible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.